Evaluation of Dose Distribution of Molecular Delivery After Blood-Brain Barrier Disruption by Focused Ultrasound with Treatment Planning
Authors:Feng-Yi Yang  Chien-Cheng Chen  Yi-Hsuan Kao  Chuan-Lin Chen  Chia-En Ko  Shih-Cheng Horng  Ran-Chou Chen
Affiliation: Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan; Department of Physical Medicine & Rehabilitation, Cheng Hsin Rehabilitation Medical Center, Taipei, Taiwan; Department of Computer Science & Information Engineering, Chaoyang University of Technology, Taichung County, Taiwan;§ Department of Radiology, Taipei City Hospital, Taipei, Taiwan
Abstract:The permeability of the blood-brain barrier (BBB) can be enhanced by focused ultrasound (FUS) in localized regions with applications of ultrasound contrast agent (UCA). The purpose of this study was to evaluate the dose distribution of Evans blue (EB) in the targeted brain by sonication with treatment strategy. FUS exposure was applied with an ultrasound frequency of 1 MHz, a 5% duty cycle and a repetition frequency of 1 Hz. Single sonication with two doses of UCA and two sonications at the same location or an interval of 3 mm to induce BBB disruption for assessing dose distribution. The permeability of the BBB was measured quantitatively based on EB extravasation. Gadolinium deposition was monitored by contrast enhanced MR imaging for dose distribution of the focal plane. Hematoxylin and eosin staining was performed for histologic observation. No significant difference was found for EB in the focal regions between the single sonication with UCA at a dose of 300 μL/kg and repeated sonication with UCA at a lower dose of 150 μL/kg. There was a sharper dose distribution in the brain with repeated sonication at the same location, compared with the brain receiving two sonications at an interval of 3 mm. Compared with a single sonication with UCA at a dose of 150 μL/kg, the histologic evaluation of the sonicated regions indicated that more erythrocytes were seen in the brain treated with single sonication at a higher dose of 300 μL/kg or repeated sonication at a dose of 150 μL/kg. This study demonstrated that the dose distribution of molecular delivery could be regulated by sonication with treatment planning.
Keywords:Focused ultrasound   Multiple sonications   Blood-brain barrier disruption   Dose distribution   Treatment planning
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号