首页 | 本学科首页   官方微博 | 高级检索  
     

基于ICF的失能评估工具在临床应用中的信度研究
引用本文:金娟,周莉,毛二莉,刘炜,李娜,严娟,励建安,刘守国. 基于ICF的失能评估工具在临床应用中的信度研究[J]. 中华物理医学与康复杂志, 2021, 43(3): 227-230
作者姓名:金娟  周莉  毛二莉  刘炜  李娜  严娟  励建安  刘守国
作者单位:南京医科大学第一附属医院康复医学科,南京 210029;江苏钟山老年康复医院,南京 210000;中国社会保障学会医疗保障专业委员会,北京 100000
基金项目:南京市重点临床专科资助课题(2019060002);中国社会保障学会医保专业委员会委托课题(Y2017003)
摘    要:目的:验证基于国际功能、残疾和健康分类(ICF)的功能评定工具在失能评估中的信度。方法:选取江苏钟山老年康复医院存在功能障碍的住院患者371例参与本研究,以基于ICF的功能评定工具对患者进行失能评估,以数字化评定量表(0~10分)评估条目失能程度。分析失能评定工具的内在一致性、评估者间信度、评估者内信度。结果:基于IC...

关 键 词:国际功能、残疾和健康分类  功能障碍  信度

The reliability of a functioning assessment tool based on the International Classification of Functioning,Disability and Health
Jin Juan,Zhou Li,Mao Erli,Liu Wei,Li Na,Yan Juan,Li Jianan,Liu Shouguo. The reliability of a functioning assessment tool based on the International Classification of Functioning,Disability and Health[J]. Chinese Journal of Physical Medicine and Rehabilitation, 2021, 43(3): 227-230
Authors:Jin Juan  Zhou Li  Mao Erli  Liu Wei  Li Na  Yan Juan  Li Jianan  Liu Shouguo
Affiliation:(Department of Rehabilitation Medicine,First Affiliated Hospital of Nanjing Medical University,Nanjing 210029,China;Jiangsu Zhongshan Geriatric Rehabilitation Hospital,Nanjing 210000,China;Medical Security Professional Committee of the Chinese Society for Social Security,Beijing 100000,China)
Abstract:Objective To investigate the reliability of a tool based on the International Classification of Functioning,Disability and Health(ICF)in the assessment of functioning despite disability.Methods A total of 371 patients were assessed using a tool based on the ICF rehabilitation set combined with a numerical rating scale ranging from 0 to 10.The internal consistency,inter-rater reliability and intra-rater reliability were analyzed.Results The scale′s Cronbach′s alpha coefficient was 0.89.The inter-rater correlation coefficient was 0.85,and the correlations among the items ranged from 0.78 to 0.94.The intra-rater correlation coefficient with the scale was 0.95,with the item correlations ranging from 0.72 to 0.97.Only item b230 Hearing function did not correlate well.Conclusions The functioning assessment tool based on the ICF rehabilitation set when combined with a numerical rating scale has internal consistency,inter-rater reliability and intra-rater reliability sufficient for use in clinical practice.
Keywords:International Classification of Functioning, Disability and Health   Dysfunction   Reliability
本文献已被 维普 等数据库收录!
点击此处可从《中华物理医学与康复杂志》浏览原始摘要信息
点击此处可从《中华物理医学与康复杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号