首页 | 本学科首页   官方微博 | 高级检索  
检索        

拉环式塑料输液瓶瓶口消毒与否的细菌检测研究
引用本文:陈泳,郑明珠,程科萍,沈吉梅,鞠昌萍.拉环式塑料输液瓶瓶口消毒与否的细菌检测研究[J].护士进修杂志,2010,25(13):1162-1163.
作者姓名:陈泳  郑明珠  程科萍  沈吉梅  鞠昌萍
作者单位:东南大学附属中大医院心内科,江苏,南京,210009
摘    要:目的检测拉环式塑料瓶瓶口消毒与不消毒的效果。方法取塑料瓶盖完整、无裂痕、无松动的每瓶250ml的0.9%氯化钠液体80瓶,随机分为对照组和实验组。对照组液体40瓶,在病区治疗室内将其液体的塑料瓶盖拉开后消毒瓶口,2min后采样;其液体40瓶,在病区治疗室内将其液体的塑料瓶盖拉开后,直接在瓶口上采样,将所取标本接种于无菌血琼脂平板培养基内,观察对照组和实验组的细菌生长情况。结果对照组与实验组的液体瓶口表面均无细菌生长。结论拉环式塑料瓶瓶口是无菌的,开启瓶盖后无需消毒即可直接临床使用。

关 键 词:输液瓶  消毒  细菌检测

Bacteria detection for infusion bottle mouth of plastic infusion containers with pull-open cap
Institution:Chen Yong, Zheng Mingzhu, Cheng Kiping, etc ( Cardiovascular Department, Affiliated Zhongda Hospital of Southeast University, Nanjing 210009 )
Abstract:Objective To evaluate the disinfection effects of the mouth of plastic infusion containers with pullopen cap. Method 80 bottles, which is cap complete, no cracks and no loosening, contain 350 ml0.9% Sodium Chloride, were ,selected and randomly divided into two groups; control and testing group. Samples were collected into the Agar culture medium two minutes after the sterilization of the bottle mouth in the treatment ward, and the testing group were sampled immediately after the bottles were opened. The bacteria flourishing in the two groups were observed. Result none of the two groups have bacteria flourishing. Conclusion The present study shows that the bot tie mouth for plastic infusion container with pull-open cap is sterilized and can be used directly without sterilization ~ again.
Keywords:Infusion bottle Disinfection Bacteria detection
本文献已被 CNKI 维普 万方数据 等数据库收录!