首页 | 本学科首页   官方微博 | 高级检索  
     

同位素稀释的气相色谱-质谱法测定食品模拟物中邻苯二甲酸酯类增塑剂
引用本文:杨杰,鲁杰,崔明,方从容,赵云峰. 同位素稀释的气相色谱-质谱法测定食品模拟物中邻苯二甲酸酯类增塑剂[J]. 卫生研究, 2015, 0(1): 99-105
作者姓名:杨杰  鲁杰  崔明  方从容  赵云峰
作者单位:国家食品安全风险评估中心卫生部食品安全风险评估重点实验室;北京市大兴区疾病预防控制中心
基金项目:国家科技支撑计划(No.2011BAK10B05-02;No.2012BAK01B01)
摘    要:目的建立同位素稀释法测定4种食品模拟物中18种邻苯二甲酸酯(PAEs)类增塑剂的方法。方法水模拟物、3%(W/V)乙酸模拟物和20%乙醇模拟物中的18种增塑剂用正己烷萃取,95%乙醇模拟物加水稀释至20%乙醇后,再用正己烷萃取,采用GC-MS进行分析,同位素稀释法定性定量。结果 18种PAEs经内标校正后的线性R2≥0.9991;线性范围DINP和DIDP为0.2~5.0 mg/L,DMEP、DEEP和DBEP为0.02~2.0 mg/L,其他13种化合物的线性范围为0.005~2.0 mg/L;18种PAEs的内标相对回收率85.3%~115.0%,DIDP和DINP的定量限为200.0μg/L,其余16种PAEs的定量限为0.1~6.7μg/L,RSD≤10%。结论与以往的国标方法相比,该方法扩大了邻苯二甲酸酯类的检测范围,解决了高醇模拟物的检测结果不稳定的问题,采用同位素稀释法定性定量,结果更准确,方法更简单、可靠。

关 键 词:同位素稀释法  食品模拟物  邻苯二甲酸酯  增塑剂

Determination of phthalic acid esters plasticizer in food simulants by gas chromatography-mass spectrometry isotope dilution method
YANG Jie;LU Jie;CUI Ming;FANG Congrong;ZHAO Yunfeng. Determination of phthalic acid esters plasticizer in food simulants by gas chromatography-mass spectrometry isotope dilution method[J]. Journal of hygiene research, 2015, 0(1): 99-105
Authors:YANG Jie  LU Jie  CUI Ming  FANG Congrong  ZHAO Yunfeng
Affiliation:YANG Jie;LU Jie;CUI Ming;FANG Congrong;ZHAO Yunfeng;China National Center for Food Safety Risk Assessment,Key Laboratory of Food Safety Risk Assessment,Ministry of Health;
Abstract:Objective The isotope dilution method for determination of 18 phthalic acid esters( PAEs) plasticizer in four kinds of food simulants were developed. Methods18 PAEs were extracted by hexane in water,3%( W / V) acetic acid and 20% ethanol of food stmulant. The 95% ethanol of food simulant was diluted to 20% ethanol by water and then was extracted by hexane. Results The linear range of DINP and DIDP were 0. 2-5. 0 mg / L meanwhile the DMEP,DEEP and DBEP were 0. 02- 2. 0 mg / L,the other 13 PAEs were 0. 005- 2. 0 mg / L,the relative coefficients were greater more than 0. 9991 by internal standard calibration. The limit of detection of16 PAEs were 0. 1- 6. 7 μg / L,DIDP and DINP were 200. 0 μg / L. The average recoveries were from 85. 3% to 115. 0%with RSD less than 10%. Conclusions Compared with the previous national standard method,the detection series of phthalic acid esters were expanded. The stability of the test results were solved in simulant 95% ethanol. The method is simple and repeatable by isotope dilution statutory quantitatively.
Keywords:isotope dilution method  food simulant  phthalic acid esters  plasticizer
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号