Alter Steg, neuer Halt |
| |
Authors: | DDr D Schnabl G Rechfeld |
| |
Institution: | 1. Department Zahn-, Mund- und Kieferheilkunde und Mund-, Kiefer- und Gesichtschirurgie, Universit?tsklinik für Zahnersatz und Zahnerhaltung, Anichstr. 35, 6020, Innsbruck, ?sterreich
|
| |
Abstract: | Over the years fixed or removable prostheses are subject to wear due to function and parafunction just like the natural dentition. In implant-supported removable dentures attrition of polymer teeth and a reduction of the vertical dimension as well as wear of attachments and subsequent loss of retention may be observed. The reactivation of worn male components of Vario-Soft 3 attachments of an individually milled square bar by means of newly cast retention elements and the manufacture of a hybrid denture are presented by a case example. |
| |
Keywords: | |