摘    要:背景:磨屑引起生物学反应从而导致人工关节的无菌性松动是假体失效的主要原因,因此获取人工关节磨屑研究其生物学反应对提高人工关节寿命有重要意义。目的:获取纳米级人工关节磨损磨屑,进一步研究生物学反应。方法:通过酸消化法和酶降解法获取人工关节磨屑,比较其分离效果,并获取不同尺寸的粒子,观察纳米粒子的形态。结论与结论:①全髋关节模拟试验机运转循环次数对超高相对分子质量聚乙烯磨屑大小、形貌有一定的影响。②磨屑粒径分布范围很广,大到100 μm以上,小到小于1 μm。③从消化方法上来看,酶消化和酸消化法分离超高相对分子质量聚乙烯磨屑有效可行。

关 键 词:磨屑  人工关节  超高相对分子质量聚乙烯  分离  表征  
收稿时间:2011-10-11

Isolation and description of the artificial joint wear debris
Wei Hui-hui,Liu Hong-tao,Cao Xi-chuan,Jia Yu-mei. Isolation and description of the artificial joint wear debris[J]. Chinese Journal of Tissue Engineering Research, 2012, 16(26): 4776-4780. DOI: 10.3969/j.issn.1673-8225.2012.26.006
Authors:Wei Hui-hui  Liu Hong-tao  Cao Xi-chuan  Jia Yu-mei
Affiliation:School of Materials Science and Engineering, China University of Mining and Technology, Xuzhou 221008, Jiangsu Province, China
Abstract:BACKGROUND:Aseptic loosening of artificial joints resulted by wear debris caused biological response is the main reason for prosthesis failure. Therefore, to obtain the artificial joints wear debris and to study the biological response is important for the improvement of artificial joint life.OBJECTIVE:To obtain the nanoscale artificial joints wear debris, and to further study the biological response.METHODS:The artificial joints wear debris was obtained by acid digestion and enzymatic degradation methods and the separation efficiency of these two methos was compared. Different sizes of particles were obtained and the morphology of nanoparticles was observed.RESULTS AND CONCLUSION:①The operation cycle times of total hip simulation testing machine have a certain impact on the size and morphology of ultrahigh molecular weight polyethylene wear debris. ②The distribution range of wear debris particle size was changed from 100 μm to 1 μm. It was feasible to isolate the ultrahigh molecular weight polyethylene wear debris by acid digestion and enzymatic degradation.