首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement of relative fat content by proton magnetic resonance spectroscopy using a clinical imager
Authors:Kamba M  Meshitsuka S  Iriguchi N  Koda M  Kimura K  Ogawa T
Affiliation:Department of Radiology, Tottori University Faculty of Medicine, Yonago, Japan.
Abstract:The aim of this study was to determine the applicability of a proton magnetic resonance (MR) spectroscopy-based technique using a clinical 1.5-T MR imager for assessment of relative fat content. Proton MR spectra were obtained from a trunk phantom and 23 volunteers using a single free induction decay measurement. The ratios of fat methyl and methylene proton resonance to the water proton resonance were compared with the ratio of oil weight to water weight for the phantom, and with the ratio of body fat to lean body mass estimated by bioelectrical impedance analysis for the human subjects. Good linear relationships were found between the MR metabolite ratio and the ratio of oil weight to water weight (r = 0.9989), and the ratio of body fat to lean body mass (r = 0.9169). This MR spectroscopy-based technique is sufficiently accurate and may be applicable to assessment of human body composition.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号