首页 | 本学科首页   官方微博 | 高级检索  
检索        


PET-CT-based auto-contouring in non-small-cell lung cancer correlates with pathology and reduces interobserver variability in the delineation of the primary tumor and involved nodal volumes
Authors:van Baardwijk Angela  Bosmans Geert  Boersma Liesbeth  Buijsen Jeroen  Wanders Stofferinus  Hochstenbag Monique  van Suylen Robert-Jan  Dekker André  Dehing-Oberije Cary  Houben Ruud  Bentzen Søren M  van Kroonenburgh Marinus  Lambin Philippe  De Ruysscher Dirk
Institution:Department of Radiation Oncology (MAASTRO), GROW, University Hospital Maastricht, Maastricht, The Netherlands. angela.vanbaardwijk@maastro.nl
Abstract:PURPOSE: To compare source-to-background ratio (SBR)-based PET-CT auto-delineation with pathology in non-small-cell lung cancer (NSCLC) and to investigate whether auto-delineation reduces the interobserver variability compared with manual PET-CT-based gross tumor volume (GTV) delineation. METHODS AND MATERIALS: Source-to-background ratio-based auto-delineation was compared with macroscopic tumor dimensions to assess its validity in 23 tumors. Thereafter, GTVs were delineated manually on 33 PET-CT scans by five observers for the primary tumor (GTV-1) and the involved lymph nodes (GTV-2). The delineation was repeated after 6 months with the auto-contour provided. This contour was edited by the observers. For comparison, the concordance index (CI) was calculated, defined as the ratio of intersection and the union of two volumes (A intersection B)/(A union or logical sum B). RESULTS: The maximal tumor diameter of the SBR-based auto-contour correlated strongly with the macroscopic diameter of primary tumors (correlation coefficient = 0.90) and was shown to be accurate for involved lymph nodes (sensitivity 67%, specificity 95%). The median auto-contour-based target volumes were smaller than those defined by manual delineation for GTV-1 (31.8 and 34.6 cm(3), respectively; p = 0.001) and GTV-2 (16.3 and 21.8 cm(3), respectively; p = 0.02). The auto-contour-based method showed higher CIs than the manual method for GTV-1 (0.74 and 0.70 cm(3), respectively; p < 0.001) and GTV-2 (0.60 and 0.51 cm(3), respectively; p = 0.11). CONCLUSION: Source-to-background ratio-based auto-delineation showed a good correlation with pathology, decreased the delineated volumes of the GTVs, and reduced the interobserver variability. Auto-contouring may further improve the quality of target delineation in NSCLC patients.
Keywords:NSCLC  PET-CT  Auto-contouring  Interobserver variability  Pathology
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号