首页 | 本学科首页   官方微博 | 高级检索  
检索        


Effects of initial graft tension on the tibiofemoral compressive forces and joint position after anterior cruciate ligament reconstruction
Authors:Brady Mark F  Bradley Michael P  Fleming Braden C  Fadale Paul D  Hulstyn Michael J  Banerjee Rahul
Institution:Bioengineering Labs, Department of Orthopaedics, Brown Medical School/Rhode Island Hospital, Providence, Rhode Island 02903, USA. Braden_Fleming@brown.edu
Abstract:BACKGROUND: The initial tension applied to an anterior cruciate ligament graft at the time of fixation modulates knee motion and the tibiofemoral compressive loads. PURPOSE: To establish the relationships between initial graft tension, tibiofemoral compressive force, and the neutral tibiofemoral position in the cadaveric knee. STUDY DESIGN: Controlled laboratory study. METHODS: The tibiofemoral compressive forces and joint positions were determined in the anterior cruciate ligament-intact knee at 0 degrees , 20 degrees , and 90 degrees of knee flexion. The anterior cruciate ligament was excised and reconstructed with a patellar tendon graft using graft tensions of 1, 15, 30, 60, and 90 N applied at 0 degrees , 20 degrees , and 90 degrees of knee flexion. The compressive forces and neutral positions were compared between initial tension conditions and the anterior cruciate ligament-intact knee. RESULTS: Increasing initial graft tension increased the tibiofemoral compressive forces. The forces in the medial compartment were 1.8 times those in the lateral compartment. The compressive forces were dependent on the knee angle at which the tension was applied. The greatest compressive forces occurred when the graft was tensioned with the knee in extension. An increase in initial graft tension caused the tibia to rotate externally compared with the anterior cruciate ligament-intact knee (1.5 degrees and 7.7 degrees of external rotation when tensioned to 90 N at 0 degrees and 90 degrees of knee flexion, respectively). Increases in initial graft tension also caused a significant posterior translation of the tibia relative to the femur (0.9 and 5.3 mm of posterior translation when tensioned to 90 N at 0 degrees and 90 degrees of knee flexion, respectively). CONCLUSION: Different initial graft tension protocols produced predictable changes in the tibiofemoral compressive forces and joint positions. CLINICAL RELEVANCE: The tibiofemoral compressive force and neutral joint position were best replicated with a low graft tension (1-15 N) when using a patellar tendon graft.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号