火焰原子吸收分光光度法测定水样铅含量的不确定度评定 |
| |
引用本文: | 金凤英,李红,杨艳霞. 火焰原子吸收分光光度法测定水样铅含量的不确定度评定[J]. 中国卫生工程学, 2009, 0(6): 349-351 |
| |
作者姓名: | 金凤英 李红 杨艳霞 |
| |
作者单位: | 梅河口市疾病预防控制中心检验科,吉林梅河口135000 |
| |
摘 要: | 目的建立火焰原子吸收法分光光度测定水样中铅含量的不确定度评定方法。方法按GB/T5750.6—2006建立不确定度的数学模型,系统分析计算不确定度各分量。结果外控水样铅含量1.29mg/L时,其扩展不确定度为0.06mg/L(k=2)。结论此方法适用于评估火焰原子吸收分光光度法测定水样铅含量的不确定度。
|
关 键 词: | 原子吸收法 铅含量 不确定度评定 |
Uncertainty of Lead in Water Samples by Flame Atomic Absorption Spectrometry |
| |
Affiliation: | JIN Feng - Ying, LI Hong , YANG Yan- xia. (Meihekou Center for Disease Control and Prevention, Meihekou Jilin 135000, China) |
| |
Abstract: | Objective To establish a method for evaluating lead content uncertainty in water samples by flame atomic absorption spectrometry. Methods According to national standards( GB/T 5750. 6 - 2006), the mathematical model of uncertainty was stablished, and composed of uncertainty was analyzed and calculated. Results When the external control of lead content in water was 1.29 mg/L, the expanded uncertainty was 0. 06 mg/L(k = 2). Conclusion This method can be applied to assess lead content uncertainty in water samples by flame atomic absorption spectrometry. |
| |
Keywords: | Atomic absorption Lead content Uncertainty evaluation |
本文献已被 维普 等数据库收录! |