首页 | 本学科首页   官方微博 | 高级检索  
检索        


Measurement of the normal optic chiasm on coronal MR images.
Authors:A L Wagner  F R Murtagh  K S Hazlett  J A Arrington
Abstract:PURPOSETo develop an objective method for measuring the optic chiasm and to document its normal range in size.METHODSMeasurements of the height and area of the optic chiasm, made on coronal T1-weighted MR images with the use of commercially available region-of-interest software, were obtained in 114 healthy subjects who had a total of 123 MR studies. A normal range and standard deviation were calculated, and the information was broken down by age and sex.RESULTSThe mean area of the optic chiasm was 43.7 mm2, with a standard deviation of 5.21. The mean width was 14.0 mm, with a standard deviation of 1.68.CONCLUSIONThe area and width of the optic chiasm can be measured with the use of commercially available software, which allows an objective estimate of the chiasm''s size. Knowledge of the normal size range of the optic chiasm can be helpful in the early detection of some disorders.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号