In-111-labeled leukocyte scintigraphy in suspected orthopedic prosthesis infection: comparison with other imaging modalities
Authors:Magnuson, JE   Brown, ML   Hauser, MF   Berquist, TH   Fitzgerald, RH, Jr   Klee, GG
Affiliation:Mayo Clinic, Rochester, MN 55905.
Abstract:When infection of prosthetic orthopedic implants is suspected, optimal management requires accurate confirmation or exclusion of infection. The authors retrospectively studied 98 patients with possible infection who underwent scanning with indium-111-labeled white blood cells (WBCs) and subsequently underwent surgery within 14 days. At surgery, 50 patients had infections, as determined by means of culture or histologic results. The diagnostic accuracy of In-111 scanning was compared with that of plain radiography, arthrography, three-phase bone scanning, and various clinical and laboratory findings classically associated with infection. Positive findings on In-111 WBC scans and elevated erythrocyte sedimentation rates were found to be the most predictive variables in the diagnosis of septic prostheses (P less than or equal to .001 and P less than or equal to .002, respectively). Likelihood ratio analysis more clearly demonstrated the superiority of In-111 WBC scanning, with positive and negative scans yielding likelihood ratios of 5.0 and 0.16, respectively.