首页 | 本学科首页   官方微博 | 高级检索  
检索        


T2-weighted Dixon MRI of the spine: A feasibility study of quantitative vertebral bone marrow analysis
Authors:Ricardo Donners  Anna Hirschmann  Andreas Gutzeit  Dorothee Harder
Institution:1. Department of Radiology, University Hospital Basel, University of Basel, 4031 Basel, Switzerland;2. Institute of Radiology and Nuclear Medicine and Breast Center St. Anna, Hirslanden Klinik St. Anna, 6006 Lucerne, Switzerland;3. Department of Chemistry and Applied Biosciences, Institute of Pharmaceutical Sciences, ETH Zurich, 8093 Zurich, Switzerland;4. Department of Radiology, Paracelsus Medical University, 5020 Salzburg, Austria
Abstract:PurposeTo compare the measurements of fat fraction (FF) and in-phase vs. opposed-phase ratio between two-dimensional T2-weighted (T2W) spin-echo (SE) Dixon and three-dimensional (3D) T1-weighted (T1W) volume interpolated breath-hold examination (VIBE) Dixon sequences in malignant vertebral lesions and normal vertebral bone marrow.Materials and methodsThirty patients with focal vertebral malignancies (20 men, mean age, 67.3 ± 9.4 SD] years; age range: 41–84 years) and 30 patients without malignant spinal disease (11 men, mean age, 70.1 ± 12.9 SD]; age range: 53–93 years) were retrospectively included. Each patient underwent spine MRI at 1.5 Tesla including T2W SE and T1W VIBE 2-point Dixon sequences. Two readers independently performed 3D-volume of interest (VOI) and region of interest (ROI)-based FF and IO-ratio measurements of malignant lesions and normal vertebrae. Student t-test, Pearson correlation (r) test and two-way mixed model intraclass correlation coefficients (ICC) were used to compare measurements.ResultsT2W SE and T1W VIBE mean FF and IO-ratio were significantly smaller in malignancy compared to normal marrow, but there were significant differences of paired measurement mean values between T2W SE and T1W VIBE Dixon parameters in malignant lesions T2W SE VOI FF = 9%, T2W SE ROI FF = 7%, T2W SE IO-ratio = 4% vs. T1W VIBE VOI FF = 11%, T1W VIBE ROI FF = 9%, T1W VIBE IO-ratio = ?2%, and in normal vertebrae T2W SE VOI FF = 74%, T2W SE ROI FF = 77%, T2W SE IO-ratio = 51% vs. T1W VIBE VOI FF = 67%, T1W VIBE ROI FF = 73%, T1W VIBE IO-ratio = 58% (each P comparing the paired T2W TSE and T1W VIBE parameter, respectively < 0.001). There was excellent positive correlation between T2 W SE and T1 W VIBE-FF (r  0.99) and VOI and ROI FF measurements for each sequence (r  0.99). Inter-reader agreement was excellent for all measurements (ICC  0.94 for all).ConclusionCalculation of T2W SE Dixon derived FF is feasible and gave valid results that help discriminate between malignant vertebral lesions and normal vertebral bone marrow.
Keywords:Spine  Neoplasm  Metastasis  Magnetic resonance imaging  2D"}  {"#name":"keyword"  "$":{"id":"kw0030"}  "$$":[{"#name":"text"  "_":"Two-dimensional  3D"}  {"#name":"keyword"  "$":{"id":"kw0040"}  "$$":[{"#name":"text"  "_":"Three-dimensional  CI"}  {"#name":"keyword"  "$":{"id":"kw0050"}  "$$":[{"#name":"text"  "_":"Confidence interval  DWI"}  {"#name":"keyword"  "$":{"id":"kw0060"}  "$$":[{"#name":"text"  "_":"Diffusion weighted imaging  FF"}  {"#name":"keyword"  "$":{"id":"kw0070"}  "$$":[{"#name":"text"  "_":"Fat fraction  FO"}  {"#name":"keyword"  "$":{"id":"kw0080"}  "$$":[{"#name":"text"  "_":"Fat-only  ICC"}  {"#name":"keyword"  "$":{"id":"kw0090"}  "$$":[{"#name":"text"  "_":"Intraclass correlation coefficient  IO-ratio"}  {"#name":"keyword"  "$":{"id":"kw0100"}  "$$":[{"#name":"text"  "_":"In-/opposed-phase ratio  Ip"}  {"#name":"keyword"  "$":{"id":"kw0110"}  "$$":[{"#name":"text"  "_":"In-phase  MRI"}  {"#name":"keyword"  "$":{"id":"kw0120"}  "$$":[{"#name":"text"  "_":"Magnet resonance imaging  OP"}  {"#name":"keyword"  "$":{"id":"kw0130"}  "$$":[{"#name":"text"  "_":"Opposed-phase  RIS"}  {"#name":"keyword"  "$":{"id":"kw0140"}  "$$":[{"#name":"text"  "_":"Radiology information system  ROI"}  {"#name":"keyword"  "$":{"id":"kw0150"}  "$$":[{"#name":"text"  "_":"Region of interest  SE"}  {"#name":"keyword"  "$":{"id":"kw0160"}  "$$":[{"#name":"text"  "_":"Spin-echo  T1W"}  {"#name":"keyword"  "$":{"id":"kw0170"}  "$$":[{"#name":"text"  "_":"T1-weighted  T2W"}  {"#name":"keyword"  "$":{"id":"kw0180"}  "$$":[{"#name":"text"  "_":"T2 weighted  TSE"}  {"#name":"keyword"  "$":{"id":"kw0190"}  "$$":[{"#name":"text"  "_":"Turbo spin-echo  VIBE"}  {"#name":"keyword"  "$":{"id":"kw0200"}  "$$":[{"#name":"text"  "_":"Volume interpolated breath-hold examination  VOI"}  {"#name":"keyword"  "$":{"id":"kw0210"}  "$$":[{"#name":"text"  "_":"Volume of interest  WO"}  {"#name":"keyword"  "$":{"id":"kw0220"}  "$$":[{"#name":"text"  "_":"Water-only
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号