首页 | 本学科首页   官方微博 | 高级检索  
     


Intraabdominal pressures during natural activities in patients treated with continuous ambulatory peritoneal dialysis
Authors:Z J Twardowski  R Khanna  K D Nolph  A Scalamogna  M H Metzler  T W Schneider  B F Prowant  L P Ryan
Abstract:Intraabdominal pressures were measured during natural activities in 6 men, age 24-62 years, treated with continuous ambulatory peritoneal dialysis. The pressures were measured with a pressure transducer secured at the level of the umbilicus in the supine, sitting, and upright positions with 0-3 liters intraperitoneal fluid during talking, coughing, straining, changing position, walking, jogging, exercycling, jumping and weight lifting. Coughing and straining generated the highest intraabdominal pressures in every position. The pressures with weight lifting were proportional to the magnitude of the weight lifted up to 50 lbs, but were lower than those during coughing and straining. The pressures were generally higher with greater intraabdominal fluid volumes, especially with jumping and coughing. Exercycling was associated with lower intraabdominal pressure than was jogging, and the pressures were only minimally influenced by intraperitoneal fluid volumes. The results of this study can be used as a guide in establishing preventive measures in patients with intraperitoneal fluid to decrease complication rates related to raised intraabdominal pressures such as dialysate leaks, hernias and hemorrhoids.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号