Circulatory Effects of Hypoxia, Acute Normovolemic Hemodilution, and Their Combination in Anesthetized Pigs
Authors:Schou  Henning MD; Perez de Sa  Valeria MD; Sigurdardottir  Maria MD; Roscher  Roger MD; Jonmarker  Christer MD  PhD; Werner  Olof MD  PhD

Abstract:Background: Because hemodilution decreases the oxygen-carrying capacity of blood, it was hypothesized that severe hemodilution would decrease the tolerance to alveolar hypoxia.

Methods: Hemodynamics, oxygen transport, and blood lactate concentrations were compared in ten pigs with normal hematocrit (33 +/-4%), and ten hemodiluted pigs (hematocrit 11+/-1%; mean+/-SD) anesthetized with ketamine-fentanyl-pancuronium during stepwise decreases in inspired oxygen fraction (FIO2; 1.0, 0.35, 0.21, 0.15, 0.10, 0.05).

Results: Median systemic oxygen delivery (DO2 SY) became critical (the DO2 SY value when arterial lactate exceeded 2.0 mmol *symbol* l sup -1) at 10.4 ml *symbol* kg sup -1 min sup -1 (range 6.9-16.1) in hemodiluted animals and at 11.8 ml *symbol* kg sup -1 *symbol* min sup -1 (5.9-32.2) in animals with normal hematocrits (NS). The relationship between mixed venous oxygen saturation and arterial lactate values was less consistent and median critical mixed venous oxygen saturation was higher (P < 0.05) in the hemodiluted group (35%, range 21-64), than in animals with normal hematocrits (21%, 7-68%). In animals with normal hematocrit, decreasing FIO2 from 1.0 to 0.10 resulted in a decrease in DO2 SY from 26.3+/-9.1 to 9.3 +/-3.9 ml *symbol* kg sup -1 *symbol* min sup -1 (P < 0.01). Cardiac output did not change, systemic oxygen extraction ratio increased from 0.23+/-0.08 to 0.68+/-0.13 (P < 0.01), and arterial lactate from 0.9+/-0.2 to 3.4+/-3.0 mmol *symbol* l sup -1 (P < 0.05). Cardiac venous blood flow, as measured by retrograde thermodilution, increased from 5.7+/-2.9 to 12.6+/-5.7 ml *symbol* kg sup -1 *symbol* min sup -1 (P < 0.01). When FIO2 was reduced to 0.05, three animals became hypotensive and died. In the second group, hemodilution increased cardiac output and systemic oxygen extraction ratio (P < 0.01). Cardiac venous blood flow increased from 4.1 +/-1.7 to 9.8+/-5.1 ml *symbol* kg sup -1 *symbol* min sup -1 (P < 0.01), and cardiac venous oxygen saturation from 22+/- 5 to 41+/-10% (P < 0.01). During the subsequent hypoxia, cardiac output and DO2 SY were maintained until FIO2 = 0.15 (DO2 SY = 10.1+/-3.3 ml *symbol* kg sup -1 *symbol* min sup -1). Cardiac venous blood flow was then 18.5+/-10.7 ml *symbol* kg sup -1 *symbol* min sup -1 (P < 0.01), but in spite of this, myocardial lactate production occurred. At FIO2 = 0.10 (DO2 SY = 7.7 +/-3.0 ml *symbol* kg sup -1 *symbol* min sup -1), arterial lactate concentration increased to 8.5+/-2.3 mmol *symbol* l sup -1 (P < 0.01), and most animals became hypotensive. All hemodiluted animals died when FIO2 was decreased to 0.05 (P < 0.01 when compared to animals with normal hematocrit).

Keywords:
点击此处可从《The Journal of the American Society of Anesthesiologists》浏览原始摘要信息
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号