首页 | 本学科首页   官方微博 | 高级检索  
     


Dose-response slope of forced oscillation and forced expiratory parameters in bronchial challenge testing.
Authors:A B Bohadana  R Peslin  S E Megherbi  D Teculescu  E A Sauleau  P Wild  Q T Pham
Affiliation:Institut National de la Santé et de la Recherche Médicale, Unité 420, Epidémiologie Santé Travail, Vandoeuvre-lès-Nancy, France.
Abstract:In population studies, the provocative dose (PD) of bronchoconstrictor causing a significant decrement in lung function cannot be calculated for most subjects. Dose-response curves for carbachol were examined to determine whether this relationship can be summarized by means of a continuous index likely to be calculable for all subjects, namely the two-point dose response slope (DRS) of mean resistance (Rm) and resistance at 10 Hz (R10) measured by the forced oscillation technique (FOT). Five doses of carbachol (320 microg each) were inhaled by 71 patients referred for investigation of asthma (n=16), chronic cough (n=15), nasal polyposis (n=8), chronic rhinitis (n=8), dyspnoea (n=8), urticaria (n=5), post-anaphylactic shock (n=4) and miscellaneous conditions (n=7). FOT resistance and forced expiratory volume in one second (FEV1) were measured in close succession. The PD of carbachol leading to a fall in FEV1 > or = 20% (PD20) or a rise in Rm or R10 > or = 47% (PD47,Rm and PD47,R10) were calculated by interpolation. DRS for FEV1 (DRSFEV1), Rm (DRSRm) and R10 (DRSR10) were obtained as the percentage change at last dose divided by the total dose of carbachol. The sensitivity (Se) and specificity (Sp) of DRSRm, DRS10 delta%Rm and delta%R10 in detecting spirometric bronchial hyperresponsiveness (BHR, fall in FEV1 > or = 20%) were assessed by receiver operating characteristic (ROC) curves. There were 23 (32%) "spirometric" reactors. PD20 correlated strongly with DRSFEV1 (r=-0.962; p=0.0001); PD47,Rm correlated significantly with DRSRm (r=-0.648; p=0.0001) and PD47,R10 with DRSR10 (r=-0.552; p=0.0001). DRSFEV1 correlated significantly with both DRSRm (r=0.700; p=0.0001) and DRSR10 (r=0.784; p=0.0001). The Se and Sp of the various FOT indices to correctly detect spirometric BHR were as follows: DRSRm: Se=91.3%, Sp=81.2%; DRSR10: Se=91.3%, Sp=95.8%; delta%Rm: Se=86.9%, Sp=52.1%; and delta%R10: Se=91.3%, Sp=58.3%. Dose-response slopes of indices of forced oscillation technique resistance, especially the dose-response slope of resistance at 10Hz are proposed as simple quantitative indices of bronchial responsiveness which can be calculated for all subjects and that may be useful in occupational epidemiology.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号