首页 | 本学科首页   官方微博 | 高级检索  
     


Development and validation of an ion chromatography method for the determination of phosphate-binding of lanthanum carbonate
Authors:Raghu Samy  Patrick J. Faustino  Wallace Adams  Lawrence Yu  Mansoor A. Khan  Yongsheng Yang
Affiliation:1. Division of Product Quality Research, Office of Pharmaceutical Science, Food and Drug Administration, Life Science Building 64, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA;2. Office of Generic Drugs, Food and Drug Administration, 7519 Standish Place, Rockville, MD 20855, USA
Abstract:Lanthanum carbonate is indicated to reduce serum phosphate in patients with end stage renal disease (ESRD). When given orally, lanthanum carbonate dissociates in the acid environment of the upper gastrointestinal tract to release lanthanum ions. The free lanthanum ions bind with dietary phosphate released from food during digestion to form highly insoluble lanthanum–phosphate complexes which prevent the absorption of phosphate, consequently reduce the serum phosphate. In order to evaluate the in vitro binding capacity of lanthanum carbonate, a simple and efficient ion chromatography (IC) method was developed and validated for determination of phosphate across the pH range encountered in the gastrointestinal tract. Chromatographic separation was achieved on a Dionex ICS-2000 IC system using a Dionex AS16, IonPac (4 mm × 250 mm) analytical column and Dionex AG16, IonPac (4 mm × 50 mm) guard column. Column temperature was maintained at 30 °C. Injection volume was 10 μL. The compounds were eluted isocratically at a flow rate of 1 mL/min and detected by suppressed conductivity. The analytical method was validated according to USP Category I requirements. The validation characteristics included accuracy, precision, quantification limit, linearity, and stability. The intra-day accuracy ranged from 89% to 103% for the solutions of pH 1.2–6.8. The intra-day precision (RSD) ranged from 0.6% to 3.7% for the solutions of pH 1.2–6.8. The analytical range was linear from 2 to 200 ppm (mg/L). The R2 ranged from 0.9998 to 1.0. This method was found to be simple, robust, sensitive, specific, and accurate. It has been successfully applied for determination of phosphate binding to lanthanum carbonate over the human gastrointestinal pH range at different time-points (from 0.5 to 24 h).
Keywords:Lanthanum carbonate   Ion chromatography   Method validation   Phosphate binding
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号