首页 | 本学科首页   官方微博 | 高级检索  
     


Reduced myocardial perfusion reserve and transmural perfusion gradient in heart transplant arteriopathy assessed by magnetic resonance imaging
Authors:Muehling Olaf M  Wilke Norbert M  Panse Prasad  Jerosch-Herold Michael  Wilson Betsy V  Wilson Robert F  Miller Leslie W
Affiliation:Section of Cardiovascular MRI of the Department of Diagnostic Radiology, University of Minnesota Medical School Minneapolis, Minneapolis, Minnesota, USA. omuehlin@helios.med.uni-muenchen.de
Abstract:OBJECTIVES: The goal of this study was to detect transplant arteriopathy (Tx-CHD) by a reduced myocardial perfusion reserve (MPR) and resting endomyocardial/epimyocardial perfusion ratio (Endo/Epi ratio). BACKGROUND: Transplant arteriopathy often lacks clinical symptoms and is the reason for frequent surveillance angiography in heart transplant (Tx) recipients. Magnetic resonance perfusion imaging (MRPI) allows noninvasive assessment of transmural and selective endomyocardial and epimyocardial perfusion. METHODS: Fifteen healthy volunteers (controls) and three groups (A, B, C) of Tx recipients were included. In controls and patients, MPR (hyperemic/resting perfusion) and Endo/Epi ratio were determined with MRPI after injection of gadolinium-diethylenetriamine pentaacetic acid at rest and during hyperemia (intravenous adenosine). Group A (n = 10) had no left ventricular (LV) hypertrophy and/or prior rejection, while patients in group B (n = 10) had at least one of these characteristics. Patients in group A and B had a normal coronary angiogram and a coronary flow reserve (CFR) of > or =2.5 (CFR = hyperemic/resting blood flow). Group C (n = 7) had Tx-CHD diagnosed by angiography and a reduced CFR (<2.5). RESULTS: In group C, MPR (1.7 +/- 0.5) and Endo/Epi ratio (1.1 +/- 0.2) were significantly reduced compared with controls (4.2 +/- 0.7 and 1.6 +/- 0.3; both p < 0.0001), group A (3.6 +/- 0.7 and 1.6 +/- 0.2; both p < 0.0001) and B (2.7 +/- 0.9, p < 0.01 and 1.4 +/- 0.1, p < 0.04). Transplant arteriopathy can be excluded by an MPR of >2.3 with sensitivity and specificity of 100% and 85%. If LV hypertrophy and prior rejection are excluded, Tx-CHD can be excluded by an Endo/Epi ratio of >1.3 with 100% and 80%. CONCLUSIONS: Magnetic resonance perfusion imaging detects Tx-CHD by a decreased MPR. After exclusion of LV hypertrophy and prior rejection, resting Endo/Epi ratio alone might be sufficient to indicate Tx-CHD.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号