Evaluating the use of anti-scatter grids in adult knee radiography
Affiliation:1. Faculty of Health and Wellness Sciences, Cape Peninsula University of Technology, Office H041, Ground Floor, New Science Building, Bellville Campus, Robert Sobukwe Road, Bellville 7530, South Africa;2. Faculty of Health and Wellness Sciences & Professional Education Research Institute, Cape Peninsula University of Technology, Bellville Campus, PO Box 1906, Bellville 7535, South Africa;3. Department of Medical Imaging and Therapeutic Sciences, Cape Peninsula University of Technology, New Health Science Building, Bellville Campus, PO Box 1906, Bellville 7535, South Africa;1. Radiology Department, Memorial Sloan Kettering Cancer Center, New York, USA;2. Radiology Department, Cerrahpasa Hospital, Istanbul University, Turkey;3. Al-Hussein New Salt Hospital, Salt, Jordan;4. Cerrahpasa Hospital, Istanbul University, Turkey;5. Bursa Iznik Devlet Hospital, Istanbul, Turkey;1. Radiation Oncology Department, Institut Jules Bordet - Université Libre de Bruxelles, Brussels, Belgium;2. Inholland University of Applied Sciences, School of Health, Haarlem, the Netherlands;3. Radiation Oncology Department, Cliniques Universitaires Saint Luc, Belgium;4. Center of Molecular Imaging, Radiotherapy and Oncology (MIRO), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain, Brussels, Belgium;5. Radiography Department, Faculty of Health Sciences, University of Malta, Msida, MSD2080, Malta
Abstract:IntroductionAnti-scatter grids efficiently reduce scatter radiation from reaching the imaging receptor, enhancing image quality; however, the patient radiation dose increases in the process. There is disagreement regarding the thickness thresholds for which anti-scatter grids are beneficial. This study aims to establish a thickness threshold for the use of anti-scatter grids to optimise adult knee radiography.MethodsThe study consisted of two phases. In Phase 1 phantom knee radiographs were acquired at varying thicknesses (10–16 cm) and tube voltages (60–80 kV). For each thickness and tube voltage, images with and without an anti-scatter grid were obtained. In Phase 2, two radiologists and three radiographers, evaluated the image quality of these images. Visual Grading Analysis (VGA) scores were analysed using Visual Grading Characteristics (VGC) based on the visualisation of five anatomic criteria.ResultsThe average DAP decreased by 72.1% and mAs by 73.1% when removing the anti-scatter grid. The VGC revealed that overall images taken with an anti-scatter grid have better image quality (AUC ≥0.5 for all comparisons). However, the anti-scatter grids could be removed for thicknesses 10, 12 and 14 cm in conjunction with using 80 kVp,.ConclusionAnti-scatter grids can be removed when imaging adult knees between 10 and 12 cm using any kVp setting since the radiation dose is reduced without significantly affecting image quality. For thicknesses >12 cm, the use of anti-scatter grids significantly improves image quality; however, the radiation dose to the patient is increased. The exception is at 14 cm used with 80 kVp, where changes in image quality were insignificant.Implications for practiceOptimisation by removing anti-scatter grids in adult knee radiography seems beneficial below 12 cm thickness with any kVp value. Since the average knee thickness ranges between 10 and 13 cm, anti-scatter grid can be removed for most patients. Nevertheless, further studies are recommended to test if this phantom-based threshold applies to human subjects.
Keywords:Anti-scatter grid  Knee  Anatomical thickness  Planar radiography  Optimisation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号