首页 | 本学科首页   官方微博 | 高级检索  
检索        


The Accuracy of Acetabular Component Position Using a Novel Method to Determine Anteversion
Authors:Friedrich Boettner  Matthieu Zingg  Ahmed K Emara  Wenzel Waldstein  Martin Faschingbauer  Maximilian F Kasparek
Institution:1. Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York;2. Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Genève 14, Switzerland;3. Department of Orthopedics, Vienna General Hospital, Medical University of Vienna, Vienna, Austria;4. Department of Orthopedic Surgery, University of Ulm, Ulm, Germany
Abstract:

Background

This study compares the differences in acetabular component position, leg length discrepancy, and hip offset between the anterior and posterior approach. A novel method is applied to determine the acetabular anteversion using the C-arm tilt angle for the anterior approach.

Methods

Hundred consecutive anterior total hip arthroplasties were matched according to gender, body mass index, and age to a cohort of 100 primary total hip arthroplasties operated on through a posterior approach. Postoperative radiographs were analyzed to determine cup inclination, cup anteversion, leg length discrepancy, and hip offset.

Results

The mean inclination was 40.8° (range 33°-48°) and 45.1° (range 33°-55°) for the anterior and posterior approach, respectively. Using the new C-arm tilt plane technique, an average acetabular anteversion of 18.4° (range 11°-26°) was achieved with the anterior approach compared with 23.6° (range 8°-38°) with the posterior approach. Hundred percent cups in the anterior group and 81% in the posterior group fell within the safe zone (P < .001). There was no difference in the overall hip offset between the operated side and the contralateral side for the anterior (P = .074) and posterior (P = .919) group. There was no difference in leg length discrepancy between the 2 approaches (P = .259).

Conclusion

Intraoperative fluoroscopy-assisted direct anterior approach was associated with improved acetabular component positioning. However, no benefit was shown with regards to restoration of hip offset or leg length.
Keywords:total hip arthroplasty  anterior approach  cup position  acetabular component  intraoperative fluoroscopy
本文献已被 ScienceDirect 等数据库收录!