Performance Characteristics of a Methodology to Quantify Adverse Events over Time in Hospitalized Patients
Authors:Gareth Parry  Donald Goldmann  Kate Bones  Andrew Hackbarth  Roger Resar  Frances A. Griffin  Dale Rhoda  Cathy Murphy  Christopher P. Landrigan
Affiliation:1. Institute for Healthcare Improvement, Department of Pediatrics, Harvard Medical School, Cambridge, MA;2. Institute for Healthcare Improvement, Department of Pediatrics, Harvard Medical School, Divisions of Immunology, Infectious Diseases, and Epidemiology, Harvard School of Public Health, Cambridge, MA;3. Institute for Healthcare Improvement, Cambridge, MA;4. Pardee RAND Graduate School, RAND Corporation, Santa Monica CA;5. Public Health Research and Evaluation, Battelle Memorial Institute, Durham NC;6. Departments of Medicine, Brigham and Women's Hospital and Children's Hospital Boston, Harvard Medical School, Boston, MA.
Abstract:Objective. To assess the performance characteristics of the Institute for Healthcare Improvement Global Trigger Tool (GTT) to determine its reliability for tracking local and national adverse event rates. Data Sources. Primary data from 2008 chart reviews. Study Design. A retrospective study in a stratified random sample of 10 North Carolina hospitals. Hospital‐based (internal) and contract research organization–hired (external) reviewers used the GTT to identify adverse events in the same 10 randomly selected medical records per hospital in each quarter from January 2002 through December 2007. Data Collection/Extraction. Interrater and intrarater reliability was assessed using κ statistics on 10 percent and 5 percent, respectively, of selected medical records. Additionally, experienced GTT users reviewed 10 percent of records to calculate internal and external teams' sensitivity and specificity. Principal Findings. Eighty‐eight to 98 percent of the targeted 2,400 medical records were reviewed. The reliability of the GTT to detect the presence, number, and severity of adverse events varied from κ=0.40 to 0.60. When compared with a team of experienced reviewers, the internal teams' sensitivity (49 percent) and specificity (94 percent) exceeded the external teams' (34 and 93 percent), as did their performance on all other metrics. Conclusions. The high specificity, moderate sensitivity, and favorable interrater and intrarater reliability of the GTT make it appropriate for tracking local and national adverse event rates. The strong performance of hospital‐based reviewers supports their use in future studies.
Keywords:Patient safety  adverse event assessment  global trigger tool
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号