首页 | 本学科首页   官方微博 | 高级检索  
检索        


Comparison of the accuracy of implant position among freehand implant placement,static and dynamic computer-assisted implant surgery in fully edentulous patients: a non-randomized prospective study
Institution:1. Evidence-Based Practice Unit, Clinical Sciences Department, College of Dentistry, Ajman University, Ajman City, UAE;2. Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Berne, Switzerland;3. Texas Tech University Health Sciences Center El Paso Woody L. Hunt School of Dental Medicine, El Paso, TX;4. UCLA School of Dentistry, Division of Advanced Prosthodontics and Biomaterials Innovations and Tissue Engineering (BITE) Lab, Los Angeles, CA
Abstract:The optimal implant position is a critical factor for long-term success in fully edentulous patients. Implants can be placed through conventional freehand, static computer-assisted implant surgery (CAIS), or dynamic CAIS protocols, but at present there is very limited clinical evidence on their accuracy in fully edentulous patients. This study was performed to evaluate the accuracy of implant placement using three protocols in fully edentulous patients. Thirteen patients received 60 implants with the freehand (n = 20), static CAIS (n = 20), or dynamic CAIS (n = 20) protocol. Postoperative cone beam computed tomography was utilized to evaluate the accuracy of implant placement in relation to the planned optimal position. The data were analysed by ANCOVA followed by Bonferroni analysis. The mean angular deviation (standard deviation) in the freehand, static CAIS, and dynamic CAIS groups was 10.09° (4.64°), 4.98° (2.16°), and 5.75° (2.09°), respectively. The mean three-dimensional deviation (standard deviation) at the implant platform in the freehand, static CAIS, and dynamic CAIS groups was 3.48 (2.00) mm, 1.40 (0.72) mm, and 1.73 (0.43) mm, while at the implant apex it was 3.60 (2.11) mm, 1.66 (0.61) mm, and 1.86 (0.82) mm, respectively. No difference in terms of accuracy was found between static and dynamic CAIS; both demonstrated significantly higher accuracy when compared to the freehand protocol in fully edentulous patients.
Keywords:Dental implant  Computer-assisted surgery  Surgical navigation  Edentulous jaw  Dimensional measurement accuracy  CAIS"}  {"#name":"keyword"  "$":{"id":"key0035"}  "$$":[{"#name":"text"  "_":"computer-assisted implant surgery  CBCT"}  {"#name":"keyword"  "$":{"id":"key0045"}  "$$":[{"#name":"text"  "_":"cone beam computed tomography  DICOM"}  {"#name":"keyword"  "$":{"id":"key0055"}  "$$":[{"#name":"text"  "_":"digital imaging and communications in medicine  ANCOVA"}  {"#name":"keyword"  "$":{"id":"key0065"}  "$$":[{"#name":"text"  "_":"analysis of covariance
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号