Evaluation of optimised 3D turbo spin echo and gradient echo MR pulse sequences of the knee at 3T and 1.5T
Authors:OM Abdulaal  L Rainford  PJ MacMahon  P Kenny  F Carty  M Galligan  A Cradock  FH Alhazmi  A McGee
Institution:1. Diagnostic Radiology Technology, College of Applied Medical Sciences, Taibah University, Madina, Saudi Arabia;2. Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Dublin, Ireland;3. Department of Radiology, Mater Misericordiae University Hospital, Eccles Street, Dublin7, Dublin, Ireland;4. School of Medicine, University College Dublin, Dublin 4, Ireland
Abstract:IntroductionTo investigate the impact of parameter optimisation for novel three-dimensional 3D sequences at 1.5T and 3T on resultant image quality.MethodsFollowing institutional review board approval and acquisition of informed consent, MR phantom and knee joint imaging on healthy volunteers (n = 16) was performed with 1.5 and 3T MRI scanners, respectively incorporating 8- and 15-channel phased array knee radiofrequency coils. The MR phantom and healthy volunteers were prospectively scanned over a six-week period. Acquired sequences included standard two-dimensional (2D) turbo spin echo (TSE) and novel three-dimensional (3D) TSE PDW (SPACE) both with and without fat-suppression, and T21W gradient echo (TrueFISP) sequences. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured for knee anatomical structures. Two musculoskeletal radiologists evaluated anatomical structure visualisation and image quality. Quantitative and qualitative findings were investigated for differences using Friedman tests. Inter- and intra-observer agreements were determined with κ statistics.ResultsPhantom and healthy volunteer images revealed higher SNR for sequences acquired at 3T (p-value <0.05). Generally, the qualitative findings ranked images acquired at 3T higher than corresponding images acquired at 1.5T (p < 0.05). 3D image data sets demonstrated less sensitivity to partial volume averaging artefact (PVA) compared to 2D sequences. Inter- and intra-observer agreements for evaluation across all sequences ranged from 0.61 to 0.79 and 0.71 to 0.92, respectively.ConclusionBoth 2D and 3D images demonstrated higher image quality at 3T than at 1.5T. Optimised 3D sequences performed better than the standard 2D PDW TSE sequence for contrast resolution between cartilage and joint fluid, with reduced PVA artefact.Implications for practiceWith rapid advances in MRI scanner technology, including hardware and software, the optimisation of 3D MR pulse sequences to reduce scan time while maintaining image quality, will improve diagnostic accuracy and patient management in musculoskeletal MRI.
Keywords:MRI  3 Tesla  1  5 Tesla  3D sequences  SPACE  TrueFISP  MRI"}  {"#name":"keyword"  "$":{"id":"kwrd0045"}  "$$":[{"#name":"text"  "_":"Magnetic Resonance Imaging  TSE"}  {"#name":"keyword"  "$":{"id":"kwrd0055"}  "$$":[{"#name":"text"  "_":"Turbo Spin Echo  GRE"}  {"#name":"keyword"  "$":{"id":"kwrd0065"}  "$$":[{"#name":"text"  "_":"Gradient Echo  SNR"}  {"#name":"keyword"  "$":{"id":"kwrd0075"}  "$$":[{"#name":"text"  "_":"Signal-to-noise Ratio  PVA"}  {"#name":"keyword"  "$":{"id":"kwrd0085"}  "$$":[{"#name":"text"  "_":"Partial Volume Averaging  ROI"}  {"#name":"keyword"  "$":{"id":"kwrd0095"}  "$$":[{"#name":"text"  "_":"Region of Interest  TrueFISP"}  {"#name":"keyword"  "$":{"id":"kwrd0105"}  "$$":[{"#name":"text"  "_":"True Fast Imaging with Steady State Precession  SPAIR"}  {"#name":"keyword"  "$":{"id":"kwrd0115"}  "$$":[{"#name":"text"  "_":"Spectral Attenuated Inversion Recovery  CNR"}  {"#name":"keyword"  "$":{"id":"kwrd0125"}  "$$":[{"#name":"text"  "_":"Contrast-to-noise Ratio  TR"}  {"#name":"keyword"  "$":{"id":"kwrd0135"}  "$$":[{"#name":"text"  "_":"Repetition Time
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号