不同仪器测量中央角膜厚度的比较
引用本文:尹鸿芝,李福生,周跃华,马文博,韩彬,魏胜兰. 不同仪器测量中央角膜厚度的比较[J]. 国际眼科杂志, 2012, 12(9): 1769-1770
作者姓名:尹鸿芝  李福生  周跃华  马文博  韩彬  魏胜兰
作者单位:(100062)中国北京市,茗视光眼科诊所;(100062)中国北京市,茗视光眼科诊所;(100730)中国北京市,首都医科大学附属北京同仁医院;(100062)中国北京市,茗视光眼科诊所;(100062)中国北京市,茗视光眼科诊所;(100062)中国北京市,茗视光眼科诊所
摘    要:目的:比较光学生物测量仪、Wavelight眼前节分析仪、Galilei眼前节分析仪、光学相干断层扫描仪(OCT)与A型超声角膜测厚仪对中央角膜厚度(central corneal thickness, CCT)测量的差别。方法:选取近视眼患者74例147眼,分别应用以上5种仪器做屈光术前检查,并将前4种仪器测量结果分别与A超测量做比较。结果:A型超声角膜测厚仪测量CCT平均为537.52±31.54μm,光学生物测量仪测量CCT平均为535.32±29.74μm,比A超小2.20 ±7.29μm(t=3.67,P<0.01);Wavelight测量CCT平均为542.51±30.21μm,比A超大4.99 ±10.45μm(t=-5.79,P<0.01);Galilei测量CCT平均为546.48±27.38μm,比A超大8.95±10.44μm(t=-10.40,P<0.01);OCT测量CCT平均为530.33±28.61μm。比A超小7.20± 7.69μm(t=11.35,P<0.01)。4种仪器与A超测量结果差异有显著性。结论:在角膜厚度测量上,4种仪器与A超测厚结果存在差异,不能相互替代,可以作为参考。

关 键 词:屈光手术  角膜厚度 
收稿时间:2012-04-20
修稿时间:2012-08-06

Comparison of central corneal thickness measured by different instruments
Hong-Zhi Yin,Fu-Sheng Li,Yue-Hua Zhou,Wen-Bo M,Bin Han and Sheng-Lan Wei. Comparison of central corneal thickness measured by different instruments[J]. International Eye Science, 2012, 12(9): 1769-1770
Authors:Hong-Zhi Yin  Fu-Sheng Li  Yue-Hua Zhou  Wen-Bo M  Bin Han  Sheng-Lan Wei
Affiliation:1Ming Vision & Ophthalmology, Beijing 100062, China;2Tongren Eye Center, the Affiliated Tongren Hospital of Capital Medical University, Beijing 100730, China
Abstract:AIM:To compare the differences of central corneal thickness (CCT) measured by optical bio-measurement, Wavelight anterior segment analyzer, Galilei anterior segment analyzer, optical coherence tomography (OCT) and A-mode ultrasonic pachymeter(USP).METHODS:All 74 cases (147 eyes) with myopia were examined before refractive surgery with more than five kinds of instruments respectively, the results were compared with USP.RESULTS:CCT measured by USP was 537.52±3154μm, 535.32±29.74μm by the optical bio-measurement, which was 2.20±7.29μm less than USP(t=3.67,P<0.01). CCT was 542.51±30.21μm by Wavelight, which was 4.99±10.45μm more than USP(t=-5.79,P<0.01). CCT was 546.48±27.38μm by Galile, which was 8.95±10.44μm more than USP(t=-10.40,P<0.01). CCT was 530.33±28.61μm by OCT, which was 7.20± 7.69μm less than USP(t=11.35,P<0.01). There were significantly statistical differences between these four methods and USP.CONCLUSION:On CCT measurement, there is difference between 4 types of instruments and A scan measurement outcome. They can not instead each other, but as raference.
Keywords:refractive surgery   corneal thickness