Peritoneal scintigraphy for diagnosing periumbilical leakage in a patient on continuous ambulatory peritoneal dialysis |
| |
Authors: | Wu P S Lee B F Chiu N T Tu D G Yao W J Wang M C |
| |
Affiliation: | Department of Nuclear Medicine, National Cheng-Kung University Hospital, 138 Shing-Li Road, Tainan 704, Taiwan. |
| |
Abstract: | Continuous ambulatory peritoneal dialysis (CAPD) offers several advantages over hemodialysis for patients with end-stage renal disease; however, this technique also includes many documented complications. A case with clinical suspicion of dialysate leakage on CAPD was investigated by peritoneal scintigraphy using technetium-99m macroaggregated human albumin (99mTc-MAA). Peritoneal scintigraphy showed radiotracer accumulation over the periumbilical area at 2 hours 30 minutes after intraperitoneal infusion of 99mTc-MAA. Six hours of imaging revealed more apparent radioactivity at the same site. This study is to illustrate the simple diagnostic helpfulness of peritoneal scintigraphy in a patient with a CAPD-related structural defect. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|