首页 | 本学科首页   官方微博 | 高级检索  
     


Partial k-space reconstruction in single-shot diffusion-weighted echo-planar imaging.
Authors:Pippa Storey  Fred J Frigo  R Scott Hinks  Bryan J Mock  Bruce D Collick  Nicole Baker  Jonathan Marmurek  Simon J Graham
Affiliation:Radiology Department, Evanston Northwestern Healthcare, Evanston, Illinois 60201, USA. pstorey@enh.org
Abstract:Partial k-space sampling is frequently used in single-shot diffusion-weighted echo-planar imaging (DW-EPI) to reduce the TE and thereby improve the SNR. However, it increases the sensitivity of the technique to bulk rotational motion, which introduces a phase gradient across the tissue that shifts the echo in k-space. If the echo is displaced into the high spatial frequencies, conventional homodyne reconstruction fails, causing intensity oscillations across the image. Zero-padding, on the other hand, compromises the image resolution and may cause truncation artifacts. We present an adaptive version of the homodyne algorithm that detects the location of the echo in k-space and adjusts the center and width of the homodyne filters accordingly. The adaptive algorithm produces artifact-free images when the echo is shifted into the high positive k-space range, and reduces to the standard homodyne algorithm in the absence of bulk motion.
Keywords:diffusion imaging  motion  signal loss partial k‐space sampling  homodyne reconstruction