首页 | 本学科首页   官方微博 | 高级检索  
     

不同直径预成氧化锆桩和纤维桩修复的抗折性比较
引用本文:王效平,高卫民,陈溯,刘亦然,何薇,张振庭. 不同直径预成氧化锆桩和纤维桩修复的抗折性比较[J]. 北京口腔医学, 2013, 21(2): 89-91
作者姓名:王效平  高卫民  陈溯  刘亦然  何薇  张振庭
作者单位:北京德和诚口腔门诊部;100050北京,首都医科大学口腔医学院修复科;100050北京,首都医科大学口腔医学院特诊特需科;100050北京,首都医科大学口腔医学院老年科
基金项目:科研基地-科技创新平台,首都特色临床医学技术发展研究
摘    要:目的观察不同直径预成氧化锆桩和纤维桩与核树脂桩核冠修复上颌中切牙的抗折力。方法 24颗完整上中切牙根管充填后随机分为4组,分别采用直径1.5mm、1.35mm预成氧化锆桩和直径1.5mm、1.375mm预成纤维桩与核树脂加Ni-Cr合金铸造冠修复。对所有样本进行抗折实验,并对其断裂模式进行观察和分析。结果直径1.5mm、1.35mm预成氧化锆桩组抗折力为508.5±143.3N和434.9±141.7N,大于直径1.5mm、1.375mm的预成纤维桩组抗折力(292.2±54.5N,238.5±79.1N),差异有统计学意义(P<0.05)。预成氧化锆桩组样本的损坏模式为桩的断裂或合并根颈部的损伤,根颈部的损伤中50%为破坏性牙折;预成纤维桩组样本的损坏模式为桩的弯曲,根颈部的损伤中83.3%为可修复性牙折。结论预成氧化锆桩与核树脂桩核冠修复上颌中切牙可承受较高的载荷,预成纤维桩对预防破坏性根折有利。

关 键 词:抗折力  预成氧化锆桩  预成纤维桩

Fracture resistance of maxillary incisors restored with different diameters of prefabricated Zirconia and fiber post with core resin material
WANG Xiao-ping , GAO Wei-min , CHEN Su , LIU Yi-ran , HE Wei , ZHANG Zhen-ting. Fracture resistance of maxillary incisors restored with different diameters of prefabricated Zirconia and fiber post with core resin material[J]. Beijing Journal Of Stomatology, 2013, 21(2): 89-91
Authors:WANG Xiao-ping    GAO Wei-min    CHEN Su    LIU Yi-ran    HE Wei    ZHANG Zhen-ting
Affiliation:.VIP Clinic,Capital Medical University School of Stomatology,Beijing 100050,China
Abstract:Objective To investigate the fracture resistance of maxillary incisors restored with different diameters of prefabricated Zirconia and fiber post with core resin material. Methods Twenty-four isolated maxillary central incisors which had received root cannl treatment were divided into 4 groups, which were then restored with 1.5mm, 1.35mm diameters of Zirix post and 1.5mm, 1. 375mm diameters of fiber post, respectively. The fracture resistance of the samples was tested by universal test machine and the fracture modes were observed. Results The fracture resistance of 1.5ram and 1.35mm diameters of Zirix post was 508. 5 + 143.3N and 434. 9±141.7N,and of 1.5mm,1. 375mm diameters of fiber post was 292. 2 ±54. 5N and 238. 5 ±79. IN. There was a significant difference in resistance between prefabrieated Zirconia post and the fiber post ( P 〈 0. 05 ). 50% of the prefabricated Zirconia post samples fractured at the root cervical portion and 83. 3% of the fiber post samples fractured could be retreated. Conclusion Prefabricated Zireonia post could bear higher fracture load.
Keywords:Fracture resistance  Prefabricated Zirconia post  Prefabricated fiber post
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号