首页 | 本学科首页   官方微博 | 高级检索  
检索        

计算机辅助彩色M型超声心动图无创估测肺血管阻力的研究
引用本文:张玉奇,叶宝英,孙锟,陈笋,张志芳,沈蓉,吴兰平,高伟.计算机辅助彩色M型超声心动图无创估测肺血管阻力的研究[J].中华超声影像学杂志,2008,17(6).
作者姓名:张玉奇  叶宝英  孙锟  陈笋  张志芳  沈蓉  吴兰平  高伟
作者单位:1. 200127上海交通大学医学院附属上海儿童医学中心心内科
2. 中国福利会国际和平妇幼保健院超声科
基金项目:上海市教委高等学校青年基金 
摘    要:目的 评价自行设计的计算机软件辅助彩色M型超声心动图无创估测肺血管阻力(PVR)的可行性及准确性.方法 20例先天性心脏病患者和20例正常儿童为研究对象,应用彩色M型超声心动图检测肺动脉血流传播速度(VPE)并进行比较;应用自行设计的计算机软件测量先心病患者的肺动脉血流传播速度(VPC),并与右心导管技术所测的PVR对比.结果 先天性心脏病患者彩色M型超声测得的VPE明显低于正常儿童(38.38±18.89)cm/s对(80.34±15.65)cm/s,P<0.01],且与心导管所测的PVR值显著相关(r=-0.69,P<0.01).计算机软件测得VPC与PVR高度相关(r=-0.78,P<001),且重复性较好.VPC<35.910预测PVR>16 kPa·S·L-1的灵敏性为92.9%,特异性为100%.结论 应用计算机辅助彩色M型超声心动图技术测量肺动脉血流传播速度可以比较准确地无创估测肺血管阻力.

关 键 词:超声心动描记术  血管阻力  肺循环  心脏缺损  先天性

Study on the noninvasive estimation of pulmonary vascular resistance by color M-mode echocardiography assisted with computer
ZHANG Yu-qi,YE Bao-ying,SUN Kun,CHEN Sun,ZHANG Zhi-fang,SHEN Rong,WU Lan-ping,GAO Wei.Study on the noninvasive estimation of pulmonary vascular resistance by color M-mode echocardiography assisted with computer[J].Chinese Journal of Ultrasonography,2008,17(6).
Authors:ZHANG Yu-qi  YE Bao-ying  SUN Kun  CHEN Sun  ZHANG Zhi-fang  SHEN Rong  WU Lan-ping  GAO Wei
Abstract:Objective To determine the feasibility and accuracy of velocity propagation within main pulmonary artery(VP)from color M-mode Doppler imaging using custom software on a personal computer for noninvasive estimation of PVR.Methods Color M-mode imaging of pulmonary flow was obtained and then transferred to computer,the velocity propagation of pulmonary flow was automatically obtained.Comparative studies among Doppler echocardiography,personal computer and cardiac catheterization for predicting PVR had been done in 20 children with congenital heart disease and 20 normal children.Results Velocity propagations of children with congenital heart disease were significant lower than those of normal children obtained by color Mmode echocardiography(38.38±18.89)cm/s VS(80.34±15.65)cms,P<0.01),and correlated well with invasive PVR measurements(r=-0.69,P<0.01).The correlation and repeatability of VP obtained by the custom software were better than VP obtained by Doppler echocardiography(r=-0.78,P<0.01).A VP cutoff value obtained by the custom software of 35.910 had a sensitivity of 92.9% and a specificity of 100% to within pulmonary artery obtained by color M-mode echocardiography using custom software on a personal computer.
Keywords:Echocardiography  Pulmonary vascular resistance  Pulmonary circulation  Heart defects  congenital
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号