首页 | 本学科首页   官方微博 | 高级检索  
检索        

不同切削模式LASIK治疗中高度复性近视散光疗效
引用本文:刘兵,陈威,邵德望,文香,张梅.不同切削模式LASIK治疗中高度复性近视散光疗效[J].中国实用眼科杂志,2010,28(7).
作者姓名:刘兵  陈威  邵德望  文香  张梅
作者单位:解放军空军总医院眼科,北京,100142
摘    要:目的 评价不同切削模式LASIK治疗中高度复性近视散光的疗效.方法 应用美国雷赛LSX准分子激光机(5.3版)进行LASIK手术,常规球柱切削模式组(23只眼),术前平均裸眼视力(UCVA):0.15±0.09,球镜度数:(-4.40±2.07)D,柱镜度数(-2.42±0.47)D,随访时间(6.04±3.74)月;椭球切削模式组(33只眼),UCVA:0.13±0.05,球镜度数(-5.43±2.26)D,柱镜度数(-2.71±0.76)D,随访时间(6.91±5.10)月.结果 两组术后UCVA分别为1.11±0.17和1.05±0.10,球镜度数(-0.17±-0.77)D和(-0.18±0.89)D,柱镜度数(-0.62±0.39)D和(-0.64±0.68)D,两组间差异无统计学意义(P>0.05),术后Q值:0.60±0.35和0.29±0.59,两组间差异具有统计学意义(P<0.05).结论 LASIK 两种切削模式治疗中高度复性近视散光疗效确切、稳定,椭球型切削模式术后Q值更容易维持术前负性特征.

关 键 词:复性近视散光  角膜非球面系数Q值

Excimer Laser in different ablation model for moderate and high compound myopic astigmatism
LIU bing,CHEN Wei,SHAO De-wang,WEN Xiang,ZHANG Mei.Excimer Laser in different ablation model for moderate and high compound myopic astigmatism[J].Chinese Journal of Practical Ophthalmology,2010,28(7).
Authors:LIU bing  CHEN Wei  SHAO De-wang  WEN Xiang  ZHANG Mei
Abstract:Objective To determine the safety and efficacy of laser in situ keratomileusis (LASIK) in standard sphere/cylindrical or ellipsoidal ablation model to treat moderate and high compound myopic astigmatism. Methods The LaserSight SLX laser (5.3 software) was used in LASIK. In standard sphere/cylindrical ablation model group (23 eyes), the preoperative mean uncorrected visual acuity (UCVA) was 0.155: 0.09,sphere -4.40± 2.07D, cylinder -2.42± 0.47D, the final follow-up 6.04± 3.74 months. In ellipsoidal ablation model group (33 eyes), the UCVA was 0.13± 0.05, sphere -5.43±2.26D, cylinder-2.71± 0.76D, the final follow-up 6.91± 5.10 months. Results In two groups, the UCVA was 1.11± 0.17 and 1.05± 0.10, sphere -0.17± 0.77D and-0.18± 0.89, cylinder-0.62± 0.39D and-0.64± 0.68, respectively. No statistical different was found (P > 0.05 ). However, the postoperatively mean corneal asphericity (Q-value) was 0.60± 0.35 in sphere/cylindrical group and 0.29± 0.5928.1% (9/32) in ellipsoidai group with statistical difference. Conclusions LASIK using the LaserSight SLX excimer laser (5.3 software) in standard sphere/cylindrical or custom ellipsoidal ablation model is effective and stable for moderate and high compound myopic astigmatism. The postoperative Q-value in ellipsoidal ablation model is easier to maintain preoperatively negative characteristic.
Keywords:LASIK
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号