Inadvertent sclerostomy with encysted bleb following trans-scleral contact diode laser cyclophotocoagulation
Authors:Gupta Viney  Sony Parul  Sihota Ramanjit
Affiliation:Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
Abstract:A 22-year-old woman underwent 360 degrees trans-scleral contact diode laser cyclophotocoagulation for refractory glaucoma. Conjunctival burns and scleral thinning were noticed inferonasally at the last laser application. Intraocular pressure in the first week was normal. Six months later the patient presented with encysted filtering bleb and high intraocular pressure. Ultrasound biomicroscopy revealed a full thickness sclerostomy. This report suggests that inadvertent sclerostomy may present with encysted bleb months after trans-scleral contact diode laser cyclophotocoagulation.
Keywords:encysted bleb    inadvertent sclerostomy    trans-scleral contact diode laser cyclophotocoagulation