首页 | 本学科首页   官方微博 | 高级检索  
     


The significance of circumscribed malignant mammographic masses in the surveillance of BRCA 1/2 gene mutation carriers
Authors:R.?Kaas  author-information"  >  author-information__contact u-icon-before"  >  mailto:r.kaas@nki.nl"   title="  r.kaas@nki.nl"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author,R.?Kroger,J.?H.?C.?L.?Hendriks,A.?P.?E.?Besnard,W.?Koops,F.?A.?Pameijer,W.?Prevoo,C.?E.?Loo,S.?H.?Muller
Affiliation:(1) Department of Surgery, Netherlands Cancer Institute, Antoni van Leeuwenhoek ziekenhuis Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands;(2) Department of Radiology, Netherlands Cancer Institute, Antoni van Leeuwenhoek ziekenhuis Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands;(3) Dutch Reference Center for Breast Cancer Screening, Nijmegen, The Netherlands
Abstract:Breast cancers in gene mutation carriers may escape mammographic detection because of rapid growth and tumor expansion. Therefore, they may mimic benign lesions on the mammogram. Twenty-nine BRCA 1/2 mutation carriers under surveillance developed 31 breast cancers between 1994 and 2001 at a mean age of 44.2 years. Controls were 63 women with 67 breast cancers in the same period at a mean age of 53.8 years, also under surveillance because of a life time risk of at least 15%. In 26% of the carriers vs. 48% of the controls, mammography was the method that first suspected a malignancy. Seven radiologists performed a retrospective review of the original mammograms to establish technical assessment, with special attention for circumscribed lesions and estimated probability of malignancy. In the mutation carriers seven (23%) circumscribed non-calcified mammographic masses were found and three in the controls (4.5%) P=0.01. These masses were proven to be malignant. In both groups around 70% of these fast-growing circumscribed lesions were detected by the patients. The masses were situated in breasts with a good interpretable breast pattern. BRCA 1/2 mutation carriers had a significantly higher percentage of circumscribed non-calcified mammographic masses that proved to be malignant. These mammographic lesions in women at high risk should be described as at least Birads 0 and worked-up with ultrasound and needle biopsy.
Keywords:BRCA 1/2 gene mutation carriers  Circumscribed mammographic lesions  Surveillance  High grade breast cancers
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号