首页 | 本学科首页   官方微博 | 高级检索  
     


Computed tomography angiography: state-of-the-art imaging using multidetector-row technology
Authors:Napoli Alessandro  Fleischmann Dominik  Chan Frandics P  Catalano Carlo  Hellinger Jeffrey C  Passariello Roberto  Rubin Geoffrey D
Affiliation:Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305, USA. napolia@stanford.edu
Abstract:Multidetector-row computed tomography (MDCT) is an essential diagnostic modality for many clinical algorithms. This is particularly true with regard to the evaluation of cardiovascular disease. As a result of increased image acquisition speed, improved spatial resolution, and greater scan volume, MDCT angiography (computed tomography angiography [CTA]) has become an excellent noninvasive imaging technique, replacing intra-arterial digital subtraction angiography for most vascular territories. The clinical success of CTA depends on precise synchronization of image acquisition with optimal vascular enhancement. As technology continuously evolves, however, this task can be challenging. It remains important to have a fundamental knowledge of the principles behind technical parameters and contrast medium administration. This article reviews these essential principles, followed by an overview of current clinical applications.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号