The Diagnostic Accuracy, Image Quality and Radiation Dose of 64-Slice Dual-Source CT in Daily Practice: a Single Institution's Experience
Authors:Joon Ho Moon  Eun-Ah Park  Whal Lee  Yong Hu Yin  Jin Wook Chung  Jae Hyung Park  Hae-Young Lee  Hyun-Jae Kang  Hyo-Soo Kim
Institution:1Department of Radiology and the Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital, Seoul 110-744, Korea.;2Department of Internal Medicine and the Cardiovascular Center, Seoul National University Hospital, Seoul 110-744, Korea.
Abstract:

Objective

We wanted to evaluate the image quality, diagnostic accuracy and radiation exposure of 64-slice dual-source CT (DSCT) coronary angiography according to the heart rate in symptomatic patients during daily clinical practice.

Materials and Methods

We performed a retrospective search for the DSCT coronary angiography reports of 729 consecutive symptomatic patients. For the 131 patients who underwent invasive coronary angiography, the image quality, the diagnostic performance (sensitivity, specificity, positive predictive value PPV] and negative predictive value NPV] for detecting significant stenosis ≥ 50% diameter) and the radiation exposure were evaluated. These values were compared between the groups with differing heart rates (HR): mean HR < 65 or ≥ 65 and HR variability (HRV) < 15 or ≥ 15.

Results

Among the 729 patients, the CT reports showed no stenosis or insignificant coronary artery stenosis in 72%, significant stenosis in 26% and non-diagnostic in 2%. For the 131 patients who underwent invasive coronary angiography, 95% of the patients and 97% of the segments were evaluable, and the overall per-patient/per-segment sensitivity, the perpatient/per-segment specificity, the per-patient/per-segment PPV and the per-patient/per-segment NPV were 100%/90%, 71%/98%, 95%/88% and 100%/97%, respectively. The image quality was better in the HR < 65 group than in the HR ≥ 65 group (p = 0.001), but there was no difference in diagnostic performance between the two groups. The mean effective radiation doses were lower in the HR < 65 or HRV < 15 group (p < 0.0001): 5.5 versus 6.7 mSv for the mean HR groups and 5.3 versus 9.3 mSv for the HRV groups.

Conclusion

Dual-source CT coronary angiography is a highly accurate modality in the clinical setting. Better image quality and a significant radiation reduction are being rendered in the lower HR group.
Keywords:Dual-source computed tomography  Coronary arteries  Coronary stenosis  Coronary angiography