首页 | 本学科首页   官方微博 | 高级检索  
     

锁定钢板加缝线技术与空心拉力螺钉技术固定肱骨大结节骨折效果比较
引用本文:蔡伟,. 锁定钢板加缝线技术与空心拉力螺钉技术固定肱骨大结节骨折效果比较[J]. 中国医学工程, 2021, 0(2): 92-95
作者姓名:蔡伟  
作者单位:信阳市中医院骨科;
摘    要:目的 通过比较锁定钢板加缝线技术与空心拉力螺钉固定肱骨大结节骨折的力学稳定性,探讨优化肱骨大结节骨折的内固定方式.方法 选择信阳市中医院2015年1月至2019年4月收治的肱骨大结节骨折患者52例,按照随机数字表法分为对照组22例和观察组30例,对照组采用半螺纹松质骨空心钉固定,观察组采用小型锁定钢板固定并辅助不可吸收...

关 键 词:肱骨骨折  锁定铜板  空心钉

Comparison between locking plate and suture technique and hollow pull screw technique in fixation of humeral tubercle fracture
CAI Wei. Comparison between locking plate and suture technique and hollow pull screw technique in fixation of humeral tubercle fracture[J]. China Medical Engineering, 2021, 0(2): 92-95
Authors:CAI Wei
Affiliation:(Department of Orthopedics,Xinyang Traditional Chinese Medicine Hospital,Xinyang,Henan 464000,China)
Abstract:【Objective】To compare the mechanical stability of humeral tubercle fracture with locking plate plus suture technique and hollow pull screw fixation,and to explore the optimization of internal fixation of humeral tubercle fracture.【Methods】Fifty-two patients with humeral tubercle fracture in Xinyang Traditional Chinese Medicine Hospital from January 2015 to April 2019 were divided into two groups according to random digital table method.The control group was fixed with semithreaded cancellous bone hollow nail.The observation group was fixed with small locking plate and assisted non-absorbable suture to suture rotator cuff on the plate.The external fixation time and rehabilitation exercise were the same in the two groups.The loss of internal fixation,displacement distance above the greater tuberosity fracture block after failure,incidence of acromion impact were observed and compared between the two groups.【Results】The loss of internal fixation in the observation group was significantly smaller than that in the control group,resulting in the incidence of acromion impact less than that in the control group(P<0.05).Six months after operation,the excellent and good rate of shoulder function score was higher in the observation group than in the control group(P<0.05).【Conclusion】The fracture stability of locking plate fixation fracture block is significantly higher than that of hollow screw fixation,and the patients can receive more intensive functional exercise earlier after operation.
Keywords:humeral tubercle fracture  locking plate  hollow nail