首页 | 本学科首页   官方微博 | 高级检索  
     


Liquid chromatography-tandem mass spectrometry method for the determination of trimetazidine in human plasma
Authors:Zou Jianjun  Dai Li  Wang Guang Ji  Zhu Yubing  Fan Hongwei  Xiao Da Wei
Affiliation:Department of Clinical Pharmacology, Nanjing First Hospital Affiliated to Nanjin Medical University, Nanjing, The People's Republic of China. zoujianjun100@126.com
Abstract:A sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of trimetazidine (CAS 13171-25-0) in human plasma, using pseudoephedrine as internal standard (IS). Plasma samples were simply pretreated with methanol for deproteinization. The chromatographic separation was performed on a C18 column with a mobile phase of 3 mmol/L ammonium acetate solution-methanol (15:85, v/v) at a flow rate of 0.3 mL/min. The chromatographic separation was achieved in less than 3.2 min. The linearity was established over the concentration range of 1-100 ng/mL. Both intra- and inter-batch standard deviations were less than 9.5%. The method was successfully applied to study the relative bioavailability of trimetazidine hydrochloride tablets in healthy Chinese volunteers and the pharmacokinetic parameters of the reference and test tablets were compared.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号