首页 | 本学科首页   官方微博 | 高级检索  
检索        


Quantitation of dolastatin-10 using HPLC/electrospray ionization mass spectrometry: application in a phase I clinical trial
Authors:D A Garteiz  T Madden  D E Beck  W R Huie  K T McManus  J L Abbruzzese  W Chen  R A Newman
Institution:(1) Department of Clinical Investigation, University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030, USA, US;(2) Department of Experimental Pediatrics, University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030, USA, US;(3) TEXms Inc., 15701 West Hardy Road, Houston, Tx, 77060, XX;(4) Clinical Pharmacology Resource Facility, Box 52, University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030, USA Tel. +713-792-3608; Fax +713-792-6759, US
Abstract:A highly sensitive and specific assay for the quantitation of the anticancer agent dolastatin-10 (DOL-10) in human plasma is described. The method was based on the use of electrospray ionization-high-performance liquid chromatography/mass spectrometry (ESP-LC/MS). The analytical procedure involved extraction of plasma samples containing DOL-10 and the internal standard (DOL-15) with n-butyl chloride, which was then evaporated under nitrogen. The residue was dissolved in 50 μl mobile phase and 10 μl was subjected to ESP-LC/MS analysis using a C18 microbore column. A linear gradient using water/acetonitrile was used to keep the retention times of the analytes of interest under 5 min. The method exhibited a linear range from 0.005 to 50 ng/ml with a lower limit of quantitation (LLQ) at 0.005 ng/ml. Absolute recoveries of extracted samples in the 85–90% range were obtained. The method's accuracy (≤5% relative error) and precision (≤10% CV) were well within industry standards. The analytical procedure was applied to extract DOL-10 metabolites from samples obtained following incubation of the drug with an activated S9 rat liver preparation. Two metabolic products were detected and were tentatively identified as a N-demethyl-DOL-10 and hydroxy-DOL-10. Structural assignments were made based on the fragmentation patterns obtained using the electrospray source to produce collision-induced dissociation (CID). The method was also applied to the measurement of DOL-10 in the plasma of patients treated with this drug. Preliminary investigation of the pharmacokinetics suggested that drug distribution and elimination may be best described by a three-compartment model with t1/2α = 0.087 h, t1/2β = 0.69 h and t1/2γ = 8.0 h. Plasma clearance was 3.7 l/h per m2. Received: 17 March 1997 / Accepted: 13 June 1997
Keywords:Dolastatin-10  Dolastatin-15  Liquid chromatography atmospheric pressure  Mass spectrometry  Phase I trial
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号