A rapid method for simultaneous determination of nitrate,nitrite and thiocyanate in milk by CZE-UV using quaternary ammonium chitosan as electroosmotic flow inverter
Institution:1. Department of Chemistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil;2. Department of Sanitary and Environmental Engineering, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil;1. Key Lab of Process Analysis and Control of Sichuan Universities, Yibin University, Yibin, Sichuan, 644000, China;2. Hospital, Yibin University, Yibin, Sichuan, 644000, China;1. Department of Biochemistry, Punjab Agricultural University Ludhiana, Punjab, India;2. Genetics, ICAR- Indian Agricultural Research Institute, New Delhi, India;3. Department of Plant Breeding and Genetics,Punjab Agricultural University Ludhiana, Punjab, India;4. Molecular Biology and Biotechnology, ICAR-National Institute of Plant Biotechnology, IARI Campus, New Delhi, India;5. National Agricultural Science Fund, ICAR, New Delhi, India;6. Division of Crop Improvement, ICAR- Indian Institute of Pulses Research, Kalyanpur, Kanpur, UP, India
Abstract:This paper proposes a rapid method for the simultaneous determination of nitrate, nitrite and thiocyanate in different milk samples (cow, goat and soy) using capillary zone electrophoresis. The separations were conducted in a fused silica capillary dynamically coated with quaternary ammonium chitosan, with a total length of 48.5 cm (40 cm effective x 75 μm internal diameter) and direct detection in the UV region at 210 nm. The background electrolyte (BGE) was composed of 30 mmol L?1 of aminocaproic acid and 24 mmol L1 of perchloric acid (pH 3.85).A typical anodic electroosmotic flow of -31 × 10-9 m2 V?1 s?1 was observed at the pH of the separations. Bromate was used as the internal standard. The samples were injected by hydrodynamic pressure (50 mbar, 40 s) and the separation voltage was ?30 kV. The proposed method was validated and presented good linearity (R2> 0.99) in the linear range of 0.1–4.0 mg L?1. The ranges of the limit of detection (LOD) and limit of quantification (LOQ) were 0.03-0.04 and 0.05–0.07 mg L?1, respectively. The intra-day and inter-day precision values were better than 4.2 and 8.7 %, respectively. Recovery values ranged from 85 to 104% for the different samples of milk. The proposed method was applied in 12 commercial samples with run times of less than 2 min. The good analytical performance indicates that the method proposed is a promising alternative for the determination of nitrate, thiocyanate and nitrite in milk samples.
Keywords:Nitrate  Nitrite  Thiocyanate  Capillary zone electrophoresis  Coated capillary  Milk  Food analysis  Food composition
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号