首页 | 本学科首页   官方微博 | 高级检索  
     


Diagnostic accuracy and interobserver variability of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy in the assessment of aseptic femoral component loosening
Authors:Olivier P. P. Temmerman  Pieter G. H. M. Raijmakers  Johannes Berkhof  Erik F. L. David  Rik Pijpers  Marinus A. Molenaar  Otto S. Hoekstra  Gerrit J. J. Teule  Ide C. Heyligers
Affiliation:(1) Department of Nuclear Medicine, VU University Medical Centre, Boelelaan 1117, 1007 Amsterdam, The Netherlands;(2) Department of Orthopaedic Surgery, VU University Medical Centre, Boelelaan 1117, 1007 Amsterdam, The Netherlands;(3) Department of Clinical Epidemiology and Biostatistics, VU University Medical Centre, Boelelaan 1117, 1007 Amsterdam, The Netherlands;(4) Department of Radiology, VU University Medical Centre, Boelelaan 1117, 1007 Amsterdam, The Netherlands;(5) Department of Orthopaedic Surgery, Atrium Medical Centre, Heerlen, The Netherlands
Abstract:Background: Plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy are imaging techniques commonly used to identify aseptic femoral component loosening. Controversy exists about the relative utility of these techniques. Patients and methods: We evaluated the diagnostic accuracy and interobserver reliability of the four techniques in 78 consecutive patients (mean age 70 years, range 29–88 years) referred for evaluation of their femoral hip prostheses. The standard evaluation protocol consisted of plain radiography followed by subtraction arthrography, nuclear arthrography, and bone scintigraphy. Surgery or the subsequent clinical course of the patient was used as gold standard. Results: Overall, plain radiography had a sensitivity and specificity of 81 and 74%, respectively. Subtraction arthrography had a sensitivity of 47% and a specificity of 78%. Nuclear arthrography had a sensitivity of 69% and a specificity of 76%, and bone scintigraphy had a sensitivity of 88% with a specificity of 50%. Conclusion: We found considerable interobserver variability in all four techniques. Multivariate regression analysis revealed that bone scintigraphy and nuclear arthrography together made a significant contribution to the diagnosis when used in combination with plain radiography and are, when plain radiography is inconclusive, useful additional diagnostic techniques for the detection of femoral component loosening.
Keywords:Hip  Prostheses  Arthrography  Radiography
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号