The accuracy of goniometric measurements of proximal interphalangeal joints in fresh cadavers: comparison between methods of measurement, types of goniometers, and fingers.
Authors:Masami Kato  Ayumu Echigo  Hisaaki Ohta  Sumio Ishiai  Mitsuhiro Aoki  Sadako Tsubota  Eiichi Uchiyama
Affiliation:Department of Rehabilitation, Sapporo Medical University Hospital, Sapporo, Japan.
Abstract:This study evaluates the accuracy of goniometric measurement of fixated proximal interphalangeal (PIP) joints using fresh cadavers. Sixteen fingers in four right hands were evaluated. Angles of PIP joints obtained by three examiners, two methods (lateral, dorsal), three goniometers (plastic A, B, and a metal model), and four different fingers were compared for the accuracy of measurement. The difference of angles obtained from goniometric measurement and x-ray films of cadaver fingers was defined as "angle discrepancy." Analysis of interrater reliability proved that there was a high correlation coefficient between examiners. With the lateral method, no statistically significant difference in angle discrepancy between goniometers was observed. On the other hand, with the dorsal method, the angle discrepancy of plastic A was statistically significantly greater than plastic B in the results of two examiners (p<0.05). In both lateral and dorsal methods, the angle discrepancy of the index and ring fingers is statistically significantly greater than that of the middle and little fingers. We recommend use of the lateral method with any of the three goniometers for measurement of PIP range of motion. Goniometers with short arms are considered to be suitable for the dorsal method.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号