首页 | 本学科首页   官方微博 | 高级检索  
检索        


In Vitro Biofilm Formation on Titanium and Zirconia Implant Surfaces
Authors:Stefan Roehling  Monika Astasov‐Frauenhoffer  Irmgard Hauser‐Gerspach  Olivier Braissant  Henriette Woelfler  Tuomas Waltimo  Heinz Kniha  Michael Gahlert
Institution:1. Clinic for Oral and Cranio‐Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland.;2. Clinic for Oral and Cranio‐Maxillofacial Surgery, Cantonal Hospital Aarau, Aarau, Switzerland.;3. Clinic for Preventive Dentistry and Oral Microbiology, University Center for Dental Medicine Basel, University of Basel.;4. Center of Biomechanics & Biocalorimetry, University of Basel.;5. Department of Urology, University Hospital Basel, University of Basel.;6. Professorship for Demography, University of Bamberg, Bamberg, Germany.;7. Private practice, Munich, Germany.
Abstract:Background: It has been hypothesized that zirconia might have a reduced bacterial adhesion compared with titanium; however, results from experimental studies are rather controversial. The aim of the present study is to compare biofilm formation on zirconia and titanium implant surfaces using an in vitro three‐species biofilm and human plaque samples. Methods: Experimental disks made of titanium (Ti) or zirconia (ZrO2) with a machined (M) or a sandblasted (SLA) and acid‐etched (ZLA) surface topography were produced. An in vitro three‐species biofilm or human plaque samples were applied for bacterial adhesion to each type of disk, which after 72 hours of incubation was assessed using an anaerobic flow chamber model. Results: Zirconia showed a statistically significant reduction in three‐species biofilm thickness compared with titanium (ZrO2‐M: 8.41 μm; ZrO2‐ZLA: 17.47 μm; Ti‐M: 13.12 μm; Ti‐SLA: 21.97 μm); however, no differences were found regarding three‐species‐biofilm mass and metabolism. Human plaque analysis showed optical density values of 0.06 and 0.08 for ZrO2‐M and ZrO2‐ZLA, and values of 0.1 and 0.13 for Ti‐M and Ti‐SLA, respectively; indicating a statistically significant reduction in human biofilm mass on zirconia compared with titanium. Additionally, zirconia revealed a statistically significant reduction in human plaque thickness (ZrO2‐M: 9.04 μm; ZrO2‐ZLA: 13.83 μm; Ti‐M: 13.42 μm; Ti‐SLA: 21.3 μm) but a similar human plaque metabolism compared with titanium. Conclusion: Zirconia implant surfaces showed a statistically significant reduction in human plaque biofilm formation after 72 hours of incubation in an experimental anaerobic flow chamber model compared with titanium implant surfaces.
Keywords:Bacterial adhesion  biofilms  ceramics  dental implants  dental materials  titanium
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号