首页 | 本学科首页   官方微博 | 高级检索  
     


The attitudes to CPAP treatment inventory: development and initial validation of a new tool for measuring attitudes to CPAP treatment
Authors:ANDERS BROSTRÖM  MARTIN ULANDER  PER NILSEN  EVA SVANBORG  KRISTOFER FRANZÉN ÅRESTEDT
Affiliation:1. Department of Clinical Neurophysiology, University Hospital, Link?ping, Sweden;2. Department of Nursing Science, School of Health Sciences, J?nk?ping University, J?nk?ping, Sweden;3. Institution of Clinical and Experimental Medicine, Link?ping University, Link?ping, Sweden;4. Department of Medical and Health Sciences, Division of Health and Society, Link?ping University, Link?ping, Sweden;5. Department of Medical and Health Sciences, Division of Nursing, Link?ping University, Link?ping, Sweden;6. School of Health and Caring Sciences, Linnaeus University, Kalmar, Sweden
Abstract:Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS), but low adherence rates are common. The aim was to develop the attitudes to CPAP treatment inventory (ACTI), and to investigate the validity and reliability of the instrument among patients with OSAS. ACTI was developed on the basis of: (i) in‐depth interviews with 23 patients; (ii) examination of the scientific literature; and (iii) consensus agreement of a multi‐professional expert panel. This yielded five different types of attitudes to CPAP treatment. A prospective longitudinal design was used. Two‐hundred and eighty‐nine patients with OSAS were recruited at three different CPAP centres. Data were collected with ACTI and obtained from medical records. The homogeneity and internal consistency reliability were satisfactorily reflected by the item‐total correlations (0.59–0.81) and Cronbach’s alpha (0.89), respectively. Construct validity was confirmed with factor analysis (principal component analysis with orthogonal rotation; PCF). The PCF based on baseline data resulted in a one single‐factor solution explaining 69% of the total variance. A confirmatory factor analysis was performed 2 weeks after CPAP initiation, resulting in the same factor solution. No indication of uniform differential item functioning was found. The predictive validity was tested with receiver operating characteristic analyses, and a cut‐off of 10 on the ACTI gave a sensitivity of 93% and a specificity of 44% for CPAP termination within 6 months. The satisfactory measurement properties of this new pragmatic instrument are promising and indicate that ACTI can be useful in clinical practice to reliably measure attitudes to CPAP treatment.
Keywords:adherence  attitudes  continuous positive airway pressure  obstructive sleep apnoea syndrome  reliability  validity
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号