Clinical assessment of prosthetic valve replacement of the right-sided cardiac valves: mechanical or bioprosthesis?
Authors:M Masuda  Y Kawachi  M Oe  R Tominaga  K Kinoshita  A Nakashima  T Asou  Y Toshima  J Tanaka  K Tokunaga
Abstract:Clinical results with mechanical and bioprosthetic valve replacements for tricuspid and/or pulmonary positions were reviewed. Between February 1975 and December 1985, 34 bioprostheses (B) (22 Hancock, 9 Ionescu-Shiley and 3 Carpentier-Edwards pericardial) and 18 mechanical prostheses (M) (St. Jude Medical) were implanted in our institute excluding hospital death. Group with B included 29 tricuspid valve replacements and 5 pulmonary valve replacements. Group with M included 9 tricuspid valve replacements, 7 pulmonary valve replacements and 1 both valve replacements. The cumulative follow-up period was 207.2 patient-years (p-t) in group B and 55.0 p-y in group M. The incidence of valve failure was 0.48 +/- 0.48% per p-y in group B and 7.27 +/- 3.64% per p-y in group M (p less than 0.001). The incidence of valve-related events was 1.93 +/- 0.97% per p-y in group B and 9.09 +/- 4.07% per p-y in group M (p less than 0.001). At 3 years, the percent free of valve failure was 100 +/- 0% in group B and 76.8 +/- 10.2% in group M (p less than 0.05). Fourteen bioprosthetic valves (B') and 10 mechanical valves (M') were implanted at the right-sided cardiac valve position alone. The cumulative follow-up period was 94.2 p-y in group B' and 32.3 p-y in group M'. The incidence of valve-related events was 1.06 +/- 1.06% per p-y in group B' and 12.4 +/- 6.19% per p-y in group M' (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号