QRS subtraction for atrial electrograms: flat,linear and spline interpolations |
| |
Authors: | A. Ahmad,J. L. Salinet Suffix" >Jr.,P. Brown,J. H. Tuan,P. Stafford,G. Andre Ng,F. S. Schlindwein |
| |
Affiliation: | (1) Department of Engineering, University of Leicester, Leicester, LE1 7RH, UK;(2) Leicester NIHR Biomedical Research Unit in Cardiovascular Disease, Glenfield Hospital, Leicester, LE3 9QP, UK;(3) Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Johor Bahru, Johor, Malaysia |
| |
Abstract: | The main objective of this article is to implement and compare QRS subtraction techniques for intra-cardiac atrial electrograms based on using the surface ECG as a reference. A band-pass filter between 8 and 20 Hz followed by rectification, and then a low-pass filter at 6 Hz are used for QRS detection. QRS subtraction was performed using three different approaches: flat, linear and spline interpolations. QRS subtraction affects the power of the signals but it normally does not affect the dominant frequency. The average power of the atrial electrograms after QRS subtraction is significantly reduced for frequencies above 10 Hz. |
| |
Keywords: | |
本文献已被 PubMed SpringerLink 等数据库收录! |
|