首页 | 本学科首页   官方微博 | 高级检索  
检索        


Accuracy of sampling methods in morphometric studies of human sural nerves.
Authors:Z Cai  K Cash  P D Thompson  P C Blumbergs
Institution:Department of Neurology and University Department of Neurology, Royal Adelaide Hospital, Adelaide, South Australia.
Abstract:The aim of this study was to ascertain the minimum sample required to accurately measure the total number of myelinated fibres, mean myelinated fibre density (MFD), myelinated fibre diameter (Ds) and axonal diameter (Da) in morphometric studies of sural nerve biopsies. Measurements were obtained by sampling a single fascicle or systematic sampling of up to 50% of the total transverse fascicular area of two control and eighteen pathological sural nerves showing varying degrees of demyelination and axonal degeneration. MFD and fibre size were heterogeneous between fascicles in both control and pathological sural nerves, and morphometric results from one fascicle and systematic sampling of up to 50% of the total transverse fascicular area did not accurately represent the whole myelinated fibre population in the sural nerve. For accurate morphometric data it is necessary to quantitate all the myelinated fibres in the sural nerve.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏