Frequency and characteristics of incomplete stent apposition during and after sirolimus-eluting stent implantation
Authors:Takeuchi Hiroki  Morino Yoshihiro  Fujibayashi Daisuke  Hashida Tadashi  Kawamura Yota  Tsumuraya Naoko  Okamoto Nami  Nagaoka Masakazu  Ikari Yuji  Tanabe Teruhisa
Institution:Division of Cardiology, Department of Internal Medicine, Tokai University School of Medicine, Shimokasuya 143, Isehara, Kanagawa 259-1193.
Abstract:OBJECTIVES: Incomplete stent apposition (ISA) is frequently observed after sirolimus-eluting stent (SES) implantation. This study investigated the incidence, morphological features, and possible mechanisms of this phenomenon. METHODS: Fifty-two lesions in 47 eligible patients were treated with SES and serial intravascular ultrasound (IVUS) assessment at the time of post-intervention and 8-month follow-up. ISA was carefully identified from the IVUS images of these lesions. Specifically, quantitative two dimensional IVUS analysis was performed if the lesions demonstrated ISA, including routine IVUS parameters as well as other measurements related to ISA. RESULTS: Overall, ISA was observed in 13 lesions (25.0%) at follow-up. Persistent ISA (n = 6, 11.5%), defined as ISA consistently observed both at post-intervention and follow-up, and late-acquired ISA (n = 7, 13.5%)were systematically compared. Eighty-three percent of cases of persistent ISA were located around the stent edges, whereas all cases of late-acquired ISA were in the stent body. In the persistent ISA group, no serial changes were observed in the lumen area or external elastic membrane area (EEMA) from post-intervention to follow-up. However, in the late-acquired ISA group, EEMA and lumen area significantly increased from post-intervention to follow-up (EEMA: 13.4 +/- 3.2 vs 17.6 +/- 3.3 mm2, respectively, p < 0.0001 ; lumen area: 6.7 +/- 1.4 vs 9.2 +/- 1.8 mm2, respectively, p = 0.004). No adverse clinical events were observed in either group. CONCLUSIONS: ISA was frequently observed during and after SES implantation in clinical practice. No clinical disadvantages were observed during 16 month clinical follow-up periods. Positive remodeling may potentially cause late-acquired ISA.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号