首页 | 本学科首页   官方微博 | 高级检索  
检索        


Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model
Authors:Cheng Tang  Feng Wang  Yanjie Hou  Shanshan Lu  Wei Tian  Yan Xu  Chengzhe Jin  Liming Wang
Institution:1.Department of Orthopedic Surgery, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu 210006, China2.Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu 210006, China3.Department of Radiation Oncology, the First Affiliated Hospital of Shanxi Medical University, Taiyuan 030001, China4.Department of Radiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210006, China.
Abstract:Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.
Keywords:prosthetic joint infection  annexin V  technetium-99m  diagnosis
本文献已被 CNKI 等数据库收录!
点击此处可从《Journal of biomedical research》浏览原始摘要信息
点击此处可从《Journal of biomedical research》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号