摘    要:目的:观察H/G非骨水泥型人工全髋关节置换术后中期的随访结果。方法:对35例40髋H/G非骨水泥型人工髋关节置换术后进行了6年-10年2个月,平均7.5年的随访。临床随访根据Harris的评分方法进行评分,X线随访根据Amstutz的分区方法将股骨侧分为7个区,髋臼侧分为4个分区进行观察。结果:临床随访:Harris评分术后3年平均95分,5年平均89分,7.5年平均83分。Harris评分低于85分者6髋,其中4髋髋臼假体松动,1髋塑料内衬脱落,1髋负重疼痛。X线随访:股骨侧,股骨假体周围出现区域性透亮还25髋(62.5%),无出现全周透亮带的病例;髓腔骨骨化20髋(50.0%);假体远端骨皮质增厚18髋(45.0%);7区即股骨距处骨溶解10髋(25.0%);2髋出现7mm以内的假体下沉。髋臼侧,出现透亮带20髋(50.0%),其中区域性透亮带12髋,全周透亮带8髋,目前已有4髋施行了翻修手术;骨溶解7髋(17.5%),其中1区4髋,2区髋臼螺钉周围骨溶解3髋;骨吸收2髋(5.0%),为翻修术中植骨的病例;塑料内衬脱落1髋(2.5%)。结论:中期随访显示,临床及X线随访结果均较初期随访为差。松动关节明显增多,特别是在X线随访中,假体周围出现的异常骨反应明显高于初期随访所见。虽然目前大部分仅限于X线所见,临床上尚无症状,但应进行密切观察。此外,1髋因金属髋臼卡子松动导致塑料内衬脱落而行翻修术,此种情况应引起注意。

关 键 词:关节成形术  置换    假体失效  随访研究
修稿时间:2001-12-17

Intermediate-term results of H/G total hip arthroplasty without cement
WENLicheng,MAZhongtai,LI Jun,et al.. Intermediate-term results of H/G total hip arthroplasty without cement[J]. Chinese Journal of Orthopaedics, 2002, 22(9): 513-516
Authors:WENLicheng  MAZhongtai  LI Jun  et al.
Affiliation:WENLicheng,MAZhongtai,LI Jun,et al.Departmentof OrthopaedicSurger y,TheFirstHospitalof PekingUniversity,Beijing100034,China
Abstract:Object iv e To observe the intermediate-term results of the H /G total hip arthroplast y.Methods Thirty-fivecases(40hips)with the H /G THA were reviewed with an average of 7.5years fol-low-up(range,6to10.2years).In th is grou p,the primary lesions of hip included avascular necrosis of femoral head(1 2hips,10cases),congenital dysplasia of hip(9hips,8cases),femoral ne ck fracture(8hips,8cases),osteoarthritis(4hips,4cases),reversion(3 hips,3cases)and ankylosing spondylitis(4hips,2cas-es).The clinical res ults were scored with Harris methods.The roentgenographic results were analyzed with Am stutz meth ods.Results Theclinical average Harris scores were95in3-year follow-up,89in5-year fol-low-up,83in7.5-year follow-up. Roentgenographic results of femoral components showed20hips with in-tra medu llary ossification,18hips with cortical hypertrophy around the distal prosthe ses,25hips with lo cal re-di olucent line,10hips with osteolysis in femu r calar and2hips with implants subsiding less than7mm.Roentgenographic resul ts of acetabular component revealed20hips with radi olucent line(8compo n ents with around radiolu cent,12components with local radiolucent ),7hips with osteolysis and1hip with polyethylene lining defluxion.Conclusion Theresul ts of clinical and roentgenographic performance in mid-dle-term is not as go od as that in short-term.The abnormal bone reaction is evidently higher in mid dle-term than in short-term.Though the above-mentioned manifestation is only restricted on the roentgenogram with-out clinic symptom,however,further fol low-up is need ed.It should be noted that one case had revi sion be-cause of the polyethylene lining defluxion resulted from clip loosening on the metal ace tabular com po nent ;although this seldom happens both at home and abroad,more attention should be paid to the revi sion case re-sulted from the mechanical m alfunction not from the prosthesis loosening.
Keywords:Arthroplasty  replac ement  hip  Prosthesis failure  Follow-up studies