Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT
Authors:Wei Wang  Jian Bin Li  Hong Guang Hu  Tao Sun  Min Xu  Ting Yong Fan  Qian Shao
Institution:1.Department of Radiation Oncology (Chest Section), Shandong Cancer Hospital, 440 Jiyan Road, Jinan, Shandong, 250117, China;2.Department of Medical Physics, Shandong Cancer Hospital, 440 Jiyan Road, Jinan, Shandong, 250117, China
Abstract:This study was performed to explore and compare the dosimetric variance caused by respiratory movement in the breast during forward-planned IMRT after breast-conserving surgery. A total of 17 enrolled patients underwent the 3DCT simulation scans followed by 4DCT simulation scans during free breathing. The treatment planning constructed using the 3DCT images was copied and applied to the end expiration (EE) and end inspiration (EI) scans and the dose distributions were calculated separately. CTV volume variance amplitude was very small (11.93 ± 28.64 cm3), and the percentage change of CTV volumes receiving 50 Gy and 55 Gy between different scans were all less than 0.8%. There was no statistically significant difference between EI and EE scans (Z =–0.26, P = 0.795). However, significant differences were found when comparing the Dmean at 3DCT planning with the EI and EE planning (P = 0.010 and 0.019, respectively). The homogeneity index at EI, EE and 3D plannings were 0.139, 0.141 and 0.127, respectively, and significant differences existed between 3D and EI, and between 3D and EE (P = 0.001 and 0.006, respectively). The conformal index (CI) increased significantly in 3D treatment planning (0.74 ± 0.07) compared with the EI and EE phase plannings (P = 0.005 and 0.005, respectively). The V30, V40, V50 and Dmean of the ipsilateral lung for EE phase planning were significantly lower than for EI (P = 0.001–0.042). There were no significant differences in all the DVH parameters for the heart among these plannings (P = 0.128–0.866). The breast deformation during respiration can be disregarded in whole breast IMRT. 3D treatment planning is sufficient for whole breast forward-planned IMRT on the basis of our DVH analysis, but 4D treatment planning, breath-hold, or respiratory gate may ensure precise delivery of radiation dose.
Keywords:breast neoplasms  intensity-modulated radiotherapy  four-dimensional computed tomography  dosimetric parameters
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号