Phrases in noise test (PINT) Brazil: effectiveness of the test in children with hearing loss
Authors:Regina Tangerino de Souza Jacob  Camila Oliveira e Souza  Bruna Camilo Rosa  Larissa Germiniani dos Santos  Elaine Cristina Moreto Paccola  Bianca Gonçalves Alvarenga  José Roberto Pereira Lauris
Institution:1. Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru (FOB), Departamento de Fonoaudiologia, Bauru, SP, Brazil;2. Universidade de São Paulo (USP), Hospital de Reabilitação de Anomalias Craniofaciais (HRAC), Divisão de Saúde Auditiva, Bauru, SP, Brazil;3. Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru (FOB), Departamento de Odontopediatria, Ortodontia e Saúde Coletiva, Bauru, SP, Brazil
Abstract:IntroductionOne of the main implications of hearing impairment is the difficulty in perceiving speech sounds, especially in noisy environments. Thus, the frequency-modulated system is considered an important educational tool for children with hearing impairment because it improves speech perception in acoustically-unfavorable environments, such as in the classroom. The assessment of speech perception in noise is included in the verification protocol of this device.ObjectivesTo verify the effectiveness of the phrases in noise test Brazil in children with hearing impairment using an frequency-modulated system.MethodsThis was a cross-sectional cohort study. The sample included 40 children, aged 4 years to 11 years and 11 months old, divided into 4 groups: (1) 10 normal hearing children; (2) 13 children with hearing aids and frequency-modulated system; (3) 12 children using cochlear implant and fitted with the frequency-modulated system; and (4) 5 children diagnosed with auditory neuropathy spectrum disorder, fitted with hearing aids and/or cochlear implant and with the frequency-modulated system. The phrases in noise test Brazil was used to evaluate speech perception in noise under the conditions with and without the frequency-modulated system. For the statistical analysis of the data, a significance level of 5% (p < 0.05) was adopted.ResultsThere was a significant difference between the groups when they were evaluated with the frequency-modulated system. The test was also validated through concurrent and convergent validation measures. Phrases in noise test Brazil is a viable option for monitoring auditory performance in noise in different groups of children with hearing impairmen.ConclusionPhrases in noise test Brazil was effective in assessing speech perception in noise and may contribute to the improvement of the indication, fitting and follow-up protocols for the frequency-modulated system use.
Keywords:Speech perception  Noise  Signal to noise ratio  Hearing tests  Child
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号