首页 | 本学科首页   官方微博 | 高级检索  
     


Accuracy of MRI-guided Versus Systematic Prostate Biopsy in Patients Under Active Surveillance: A Systematic Review and Meta-analysis
Authors:Willy Baccaglini  Felipe A. Glina  Cristiano Linck Pazeto  Luis G. Medina  Fernando Korkes  Wanderley M. Bernardo  Rene Sotelo  Sidney Glina  Giancarlo Marra  Marco Moschini  Xavier Cathelineau  Rafael Sanchez-Salas
Affiliation:1. Division of Urologic Oncology, Urology Institute, University Hospitals Cleveland Medical Center, Cleveland, OH;2. Case Western Reserve University School of Medicine, Cleveland, OH;3. Department of Urology, Assiut University, Egypt;4. Core Library, University Hospitals Cleveland Medical Center, Cleveland, OH
Abstract:This meta-analysis focuses on the accuracy of upgrading to clinically significant prostate cancer (PCa) by multiparametric magnetic resonance imaging-targeted biopsy (MRI-TB) versus systematic biopsy (SB). We searched the Medline, Embase, Cochrane Central Register of Controlled Trials, Web of Science, Scopus, and Literatura Latino Americana em Ciências da Saúde databases through January 2020 for comparative, retrospective/prospective, paired-cohort, and randomized clinical trials with paired comparisons. The population consisted of patients with low-risk PCa in active surveillance with at least 1 index lesion on imaging. We evaluated the quality of evidence by using the Quality Assessment of Diagnostic Accuracy Studies-2 score. Group comparisons considered the differences between the area under the curve summary receiver operating characteristic curve in a 2-tailed method. We also compared the positive predictive value of the best single method (MRI-TB or SB) and the referral study test (combined biopsy, a combination of MRI-TB and SB). The meta-analysis included 6 studies enrolling 741 patients. The pooled sensitivity for the 2 groups was 0.79 (95% confidence interval, 0.74-0.83; I2 = 75%) and 0.67 (95% confidence interval, 0.63-0.74; I2 = 55.4%), respectively. The area under the curve for the MRI-TB and SB groups were 0.99 and 0.92 (P < .001), respectively. The positive predictive value for the MRI-TB and combined biopsy groups were similar. The accumulated evidence suggests better results for MRI-TB compared with SB. Therefore, use of MRI-TB alone may be preferable in patients in active surveillance harboring low-risk PCa.
Keywords:Diagnosis  Prostate cancer  Systematic biopsy  Target biopsy  Upgrading
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号